This study developed a complexometric
titration simulation program
based on LabVIEW. With built-in approximation and rigorous algorithms,
the program can easily simulate and plot a single or a group of complexometric
titration curves. On the basis of this program, we developed and implemented
an online course to guide undergraduates to (i) compare the differences
between the two titration types EDTA (Y) to Metal (M) and M to Y,
(ii) explore the influencing factors of a titration jump, (iii) explore
the conditions for an accurate titration, and (iv) find evidence for
the existence of complexometric equilibrium. Questionnaires from 25
students were used for evaluation. The results showed that the program
had high usability, practicability, effectiveness, and user behavior
intention. Besides, 92% of the students were willing to use it more
in the future and 11 students completed the test with an average score
of 124.6 (full score of 150), and the average score of the modules
corresponding to each learning goal was high, indicating that the
students had achieved satisfactory learning outcomes.