2013
DOI: 10.1016/j.prosdent.2013.09.003
|View full text |Cite
|
Sign up to set email alerts
|

Creating labial bone for immediate implant placement: A minimally invasive approach by using orthodontic therapy in the esthetic zone

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(14 citation statements)
references
References 18 publications
0
14
0
Order By: Relevance
“…Regarding the orthodontic implant site development, the most used appliance to perform orthodontic extrusion was a multi-bracket system; in only one study [ 9 ], a removable appliance was used. The multi-bracket approach was full bimaxillary in three studies [ 14 , 29 , 30 ] and partial in seven studies [ 5 , 7 , 8 , 10 , 11 , 12 , 13 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Regarding the orthodontic implant site development, the most used appliance to perform orthodontic extrusion was a multi-bracket system; in only one study [ 9 ], a removable appliance was used. The multi-bracket approach was full bimaxillary in three studies [ 14 , 29 , 30 ] and partial in seven studies [ 5 , 7 , 8 , 10 , 11 , 12 , 13 ].…”
Section: Resultsmentioning
confidence: 99%
“…Different ways were employed to apply the extrusive force: three studies [ 8 , 13 , 29 ] used NiTi archwires and a more apical bonding of brackets on the teeth to be extruded; one study [ 9 ] used elastic bands from orthodontic hooks bonded to the cervical region of teeth to be extruded and a removable appliance; one study [ 14 ] first used NiTi archwires and a more apical bonding of brackets, then an SS archwire with extrusion steps and intermaxillary elastics; three studies [ 10 , 11 , 12 ] used SS archwires and extrusion steps; one study [ 7 ] used a Co-Cr archwire with extrusion steps, L-loops and inset component for palatal movement; and one study [ 30 ] used an SS archwire with L-shape loops.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Regarding the follow-up time periods (Table 3), not all studies showed data about it. Longer follow-up time periods ranging from a minimum of one year to a maximum of five years are found only in the studies of Watanabe et al [22] and Hochman et al [5]. Amato et al [19] reports a range of "bone gain" between 0.6 mm and 8 mm on a total of 32 elements analysed while in another study [25] Kwon et al found that the average bone increase at the interproximal level was 1.36 mm considering 11 elements.…”
Section: Discussionmentioning
confidence: 97%
“…mm extrusion/month OC FB FU X-ray 0-1mm 1-2mm >2 mm H. Salama and M. Salama [10] 3m X-ray Linear 2-D Korayem et al [16] 7 m-3 y Linear 2-D Brindis and Block [6] Uribe et al [17] Kim et al [18] 5y X-ray Linear 2-D Amato et al [19] 18-61 m Linear 2-D Rokn et al [20] 4 m X-ray Linear 2-D Linear 2-D Chou et al [21] 2y X-ray Watanabe et al [22] 4y CBCT Volume 3-D Hochman et al [5] 1y CBCT Linear 3-D Keceli et al [23] 12 m Linear 2-D Alsahhaf and Att [24] Kwon et al [25] Linear 2-D 6 e Scientific World Journal Table 4: Data from the literature review in which the parameter of the stabilization times was compared (grey filled box � yes applied).…”
Section: -20gmentioning
confidence: 99%