“…Values of SSS, SRS and SDS on stress-rest Tl-201 gated SPECT were automatically calculated with QPS and HSV using a normal database developed for Japanese patients. 13) Reverse redistribution on a rest Tl-201 SPECT image was not reflected in the SDS, and it was considered to be zero. Regional SSS, SRS and SDS in apical, mid and basal areas were also calculated to evaluate the characteristics of each software.…”
Section: Methodsmentioning
confidence: 99%
“…Values of SSS, SRS and SDS on stress-rest Tl-201 gated SPECT were automatically calculated with QPS and HSV using a normal database developed for Japanese patients. 13) Reverse redistribution on a rest Tl-201 SPECT image was not reflected in the SDS, and it was considered to be zero. Regional SSS, SRS and SDS in apical, mid and basal areas were also calculated to evaluate the characteristics of each software.…”
Section: Methodsmentioning
confidence: 99%
“…The severity of the attenuation artifact can be influenced by the energy of the incident photon [19]. Therefore attenuation of 201 Tl is more marked than for 99m Tc [8,20]. Experienced nuclear cardiologists can recognize the artifacts of the inferior wall with information of regional wall motion, differentiating attenuation artifact from myocardial scarring.…”
Section: Iq-spect/ct Systemmentioning
confidence: 99%
“…With IQ-SPECT, it is possible to perform MPI scans in one-fourth the time or using one-fourth the administered dose as compared to a standard protocol using parallel-hole collimators [6][7]. In Japan, thallium-201 ( 201 Tl) myocardial perfusion study is conducted in more than 50% of stress examinations [8]. It was reported that there was a significant difference between Japanese and Western populations and that the best diagnostic accuracy was obtained by using the populationand orbit-specific normal database [9].…”
Section: Introductionmentioning
confidence: 99%
“…The JSNM working group database for myocardial perfusion tracers was created in 2007, and the characteristics of the database, backgrounds of a low-likelihood of coronary artery diseases, type of tracers and acquisition conditions were described elsewhere [4]. Briefly, the perfusion databases consisted of 326 sets of short-axis images, and they were classified into male/female, 180°/360° and tracer type combinations.…”
Section: Jsnm 2007 Databasementioning
confidence: 99%
“…In the preceding studies, although visual evaluation of extent and severity of ischemia was essential, quantitative analysis aided or enhanced a diagnostic accuracy [1][2][3]. Since appropriate normal databases matching those of the acquisition parameters, genders and types of tracers were considered indispensable, we accumulated normal databases from multiple institutions as the working group activity of the Japanese Society of Nuclear Medicine (JSNM) [4][5][6]. Our aim was to use one common standard database for multiple centers with nuclear medicine facilities.…”
Section: Introductionmentioning