2018
DOI: 10.1088/1742-6596/1059/1/012013
|View full text |Cite
|
Sign up to set email alerts
|

Creation of the Information System Based on Experimental Data for Control of the MMF Operating Modes to Improve the Efficiency of Ventilation in Mines

Abstract: Abstract. The paper presents the results of two experiments conducted using the main mine fan in BKPRU-2 mine (PJSC Uralkali, Russia). The obtained data processing showed that a statistical verification of the measured data on their falsity and independence should be performed to effectively control the ventilation process. The mathematical dependences are provided for calculating the total natural draft during measurements, which significantly affects the ventilation process. This enables the control of venti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 8 publications
0
2
0
Order By: Relevance
“…Two experiments were held at the same mine (Bereznyaki Mine 2 of Uralkali) using the same MMF operating modes but at different times of the year: in summer (in June, the outdoor temperature is +21.8 °C) and in winter when air heaters are running (in February, the outdoor temperature is -2.1 °C). The results of the experiments are presented in [5].…”
Section: Body Of the Papermentioning
confidence: 99%
See 1 more Smart Citation
“…Two experiments were held at the same mine (Bereznyaki Mine 2 of Uralkali) using the same MMF operating modes but at different times of the year: in summer (in June, the outdoor temperature is +21.8 °C) and in winter when air heaters are running (in February, the outdoor temperature is -2.1 °C). The results of the experiments are presented in [5].…”
Section: Body Of the Papermentioning
confidence: 99%
“…The operation mode of the mine airing system and the stability of the ventilation process determine the safety of the underground mining workings [1][2][3][4]. Fresh air is supplied to the mine using the main mine fan (MMF), which operation is influenced by a large number of disturbing factors [5]. The volume of the incoming airflow is constantly changing, the capacity of the MMF is exceeded by 5-15% [6,7].…”
Section: Introductionmentioning