Criteria for the identification of compounds by liquid chromatography–mass spectrometry and liquid chromatography–multiple mass spectrometry in forensic toxicology and doping analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
118
0
3

Year Published

2004
2004
2022
2022

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 183 publications
(123 citation statements)
references
References 31 publications
2
118
0
3
Order By: Relevance
“…Routine confirmation and quantitation was performed in the selected-ion monitoring (SIM) mode with respect to three significant ions for each compound and two for each IS. Positive confirmation utilizing three significant ions was in accordance with published recommendations [31]. The mass-to-charge ratios (m/z) of the analyte ions used for quantitation in SIM mode are indicated in Table 1.…”
Section: Gc-ms Proceduresmentioning
confidence: 80%
“…Routine confirmation and quantitation was performed in the selected-ion monitoring (SIM) mode with respect to three significant ions for each compound and two for each IS. Positive confirmation utilizing three significant ions was in accordance with published recommendations [31]. The mass-to-charge ratios (m/z) of the analyte ions used for quantitation in SIM mode are indicated in Table 1.…”
Section: Gc-ms Proceduresmentioning
confidence: 80%
“…For a confirmatory analysis in forensic toxicology, guidelines require chromatographic separation and at least three ions for compound detection or identification with SIM when a single quadrupole GC-MS is used [23]. For the identification of residues by LC-MS/MS analysis, European guidelines require chromatographic separation and a minimum of two transitions for substance detection; when LC-MS (single MS) is used, three characteristic ions are required [24,25]. None of the published LC-MS or LC-MS/MS methods for EtG listed in Table 1 fulfilled these requirements, since either only one ion with optimized "in-source" CID conditions was used with a single-quadrupole instrument [4,11], or only one …”
mentioning
confidence: 99%
“…When the results of urine drug testing can affect an individu-al's reputation, job status, or freedom, forensicallyacceptable analytical procedures must be utilized, and the findings legally defensible. For a confirmatory analysis in forensic, veterinary, or environmental toxicology, international guidelines require chromatographic separation and at least one precursor ion with two product ions for compound detection and identification by LC-MS/MS or monitoring of three selected ions with single-stage MS instruments [11][12][13]. LC-ESI-MS/MS seems to be the method of choice for forensic confirmatory analysis of EtS.…”
mentioning
confidence: 99%