2024
DOI: 10.3389/fped.2024.1373913
|View full text |Cite
|
Sign up to set email alerts
|

Criteria of ultrasound-guided closed reduction with percutaneous pinning in unstable humeral lateral condylar fractures: a three-center retrospective cohort study

Xiuming Huang,
Chaoyu Liu,
Guoqiang Jia
et al.

Abstract: BackgroundInterventions using ultrasound-guided closed reduction and percutaneous pinning (UG-CRPP) of humeral lateral condylar fractures (HLCFs) have been increasingly applied; however, their effectiveness for unstable HLCFs and the criteria for ultrasound outcomes remain unclear. This study assessed the outcomes of UG-CRPP for HLCFs and evaluated the success criteria in children.MethodsData were retrospectively collected from 106 patients with unstable HLCFs admitted to three hospitals between January 2021 a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 31 publications
0
1
0
Order By: Relevance
“…A retrospective study conducted by Su et al compared two groups of patients undergoing reduction and stabilization with Kirschner wires and absorbable screws, for a total of 86 cases, stating that there is no statistically significant difference in clinical and radiographic outcomes between the two groups [27]. Results concerning the application of ultrasound guidance for closed fracture reduction have recently been published in the literature [28]. This technique is very effective because it involves minimal blood loss, minimal surgical incision and no exposure to X-rays, but it is dependent on the skills of the surgeon and cannot be applied to all types of fractures, such as those requiring open reduction.…”
Section: Discussionmentioning
confidence: 99%
“…A retrospective study conducted by Su et al compared two groups of patients undergoing reduction and stabilization with Kirschner wires and absorbable screws, for a total of 86 cases, stating that there is no statistically significant difference in clinical and radiographic outcomes between the two groups [27]. Results concerning the application of ultrasound guidance for closed fracture reduction have recently been published in the literature [28]. This technique is very effective because it involves minimal blood loss, minimal surgical incision and no exposure to X-rays, but it is dependent on the skills of the surgeon and cannot be applied to all types of fractures, such as those requiring open reduction.…”
Section: Discussionmentioning
confidence: 99%