2012
DOI: 10.1039/c2ja30024a
|View full text |Cite
|
Sign up to set email alerts
|

Critical aspects of sample handling for direct nanoparticle analysis and analytical challenges using asymmetric field flow fractionation in a multi-detector approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
70
0
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 99 publications
(71 citation statements)
references
References 52 publications
0
70
0
1
Order By: Relevance
“…Use of nonionic surfactant (Triton X-100) having relatively lower value of zeta potential led to a nearcomplete separation from the void peak, allowing particle approach closer to the channel wall (Ulrich et al 2012). Meanwhile, the attractive van der Waals force could be increased with reduction in the distance between particle and channel surface, resulting in a lower sample recovery (Ulrich et al 2012).…”
Section: Optimization Of Sdfff For Analysis Of Fe 3 O 4 Mnpsmentioning
confidence: 98%
“…Use of nonionic surfactant (Triton X-100) having relatively lower value of zeta potential led to a nearcomplete separation from the void peak, allowing particle approach closer to the channel wall (Ulrich et al 2012). Meanwhile, the attractive van der Waals force could be increased with reduction in the distance between particle and channel surface, resulting in a lower sample recovery (Ulrich et al 2012).…”
Section: Optimization Of Sdfff For Analysis Of Fe 3 O 4 Mnpsmentioning
confidence: 98%
“…(84) There are various techniques and approaches which allow direct analysis of NPs by getting not only information on chemical composition but also size simultaneously. (85) The particle size, which includes size distribution and aggregation state, is arguably one of the most important properties to quantify biodistribution of NPs and when conducting toxicity tests. (86) In relation to ICPMS, other approaches for solution/diluted suspensions show potential to be applied:…”
Section: Future Challenges Of Inductively Coupled Plasma Mass Spectromentioning
confidence: 99%
“…The chosen setting of the plasma power is of great importance for achieving a complete ionization of particles up to the micrometer size. (1,85) Beyond method sensitivity limitations, many current techniques have been shown to be well suited to characterize polydisperse systems that contain aggregates. (86) sp-ICPMS is an emerging analytical technique that has the potential of addressing some of the major challenges faced by investigators when analyzing for particle size within toxicity tests.…”
Section: Single-particle (Sp) Mode Icpmsmentioning
confidence: 99%
See 1 more Smart Citation
“…Uncontrolled particle-membrane interactions can lead to changes on the NPs elution time [163] NPs in coffee creamer [55] ], tomato soup [29] and also for TiO 2 NPs in sunscreens [52].…”
Section: Field-flow Fractionationmentioning
confidence: 99%