2012
DOI: 10.1039/c2ay25379h
|View full text |Cite
|
Sign up to set email alerts
|

Critical evaluation of methods for end-point determination in pharmaceutical blending processes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 52 publications
0
8
0
Order By: Relevance
“…The MBSD method is straightforward and easily implemented, but provides inaccurate predictions owing to its poor sensitivity for identifying the blending end-point as a result of the strong effects of spectral variation and noise. 12 , 23 The PC-SDA method provided results on a par with those of the PLS method; like MBSD, however, it is subject to the deleterious effects of spectral variations and noise [ Figure 4(f)]. In contrast, the PC-SDA method requires no reference and its threshold is statistically calculated and, hence, reproducible.…”
Section: Pls Calibration Methodsmentioning
confidence: 99%
“…The MBSD method is straightforward and easily implemented, but provides inaccurate predictions owing to its poor sensitivity for identifying the blending end-point as a result of the strong effects of spectral variation and noise. 12 , 23 The PC-SDA method provided results on a par with those of the PLS method; like MBSD, however, it is subject to the deleterious effects of spectral variations and noise [ Figure 4(f)]. In contrast, the PC-SDA method requires no reference and its threshold is statistically calculated and, hence, reproducible.…”
Section: Pls Calibration Methodsmentioning
confidence: 99%
“…In this study, three consecutive spectra based on all wavelengths were used, while one spectrum was moved at a time. The detailed computing formula for MBSD can be found in the relevant reference [13] .…”
Section: Multivariate Modelingmentioning
confidence: 99%
“…Mixing time has been assessed for different blending processes: for instance, NIR probes were applied to a modified V-blender (Sekulic et al, 1996), a Nauta mixer (Berntsson et al, 2002) and a lab-scale blender (Blanco et al, 2002). Further applications can be found in the work of Blanco, Cueva-Mestanza et al (2012) which provided a good review of blending time assessment and a detailed comparison of the different methods and pre-treatments. Given the great success of NIR in estimating the end time of powder blending, this technique was also employed to monitor and determine the end time of other processes.…”
Section: A C C E P T E D Accepted Manuscriptmentioning
confidence: 99%