2022
DOI: 10.1016/j.aca.2021.338828
|View full text |Cite
|
Sign up to set email alerts
|

Critical review of analytical methods for the determination of flame retardants in human matrices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 172 publications
0
5
0
Order By: Relevance
“…Śmiełowska and Zabiegała (2020a) reviewed current solutions used for sample preparation and respective future trends for PBDE analysis. Hajeb et al (2021) performed a critical review of analytical methods for the determination of PBDEs and a number of other BFRs in human matrices. Co-extracted lipids and other interfering compounds can be removed in several ways, such as gel permeation chromatography (GPC), aluminium-oxide chromatography and multilayer silica chromatography.…”
Section: Methods Of Analysismentioning
confidence: 99%
“…Śmiełowska and Zabiegała (2020a) reviewed current solutions used for sample preparation and respective future trends for PBDE analysis. Hajeb et al (2021) performed a critical review of analytical methods for the determination of PBDEs and a number of other BFRs in human matrices. Co-extracted lipids and other interfering compounds can be removed in several ways, such as gel permeation chromatography (GPC), aluminium-oxide chromatography and multilayer silica chromatography.…”
Section: Methods Of Analysismentioning
confidence: 99%
“…It is impossible to select a single biological matrix that encompasses the global population, as well as all target compounds. Due to the lipophilic nature of PBDEs and HBCDDs, they are best evaluated through matrices such as blood serum or breast/maternal milk . Breast milk has a high lipid content and can be collected noninvasively, making it a reliable and accessible matrix for assessing body burdens of PBDEs and HBCDDs, as well as many other POPs.…”
Section: Methodsmentioning
confidence: 99%
“…Due to the lipophilic nature of PBDEs and HBCDDs, they are best evaluated through matrices such as blood serum or breast/ maternal milk. 72 Breast milk has a high lipid content and can be collected noninvasively, making it a reliable and accessible matrix for assessing body burdens of PBDEs and HBCDDs, as well as many other POPs. The Stockholm Convention, in cooperation with the World Health Organization, has identified human milk as a core matrix of its Global Monitoring Plan and supported with routine quantification in pooled milk samples.…”
Section: Rationalization Of Study Matrixmentioning
confidence: 99%
“…The extensive application and widespread production of TBBPA have given rise to neurotoxicity, immunotoxicity, endocrine disruption, carcinogenic effects, and developmental and reproductive toxicity. 11 Hence, there is an urgent need to detect BPs in environmental samples to evaluate the environmental pollution status and apply corresponding governance measures.…”
Section: Introductionmentioning
confidence: 99%
“…However, these substitutes are not necessarily safer than BPA, exhibiting an estrogenic effect equal to or even stronger than BPA. ,, Tetrabromobisphenol A (TBBPA) is extensively utilized as a flame retardant. The extensive application and widespread production of TBBPA have given rise to neurotoxicity, immunotoxicity, endocrine disruption, carcinogenic effects, and developmental and reproductive toxicity . Hence, there is an urgent need to detect BPs in environmental samples to evaluate the environmental pollution status and apply corresponding governance measures.…”
Section: Introductionmentioning
confidence: 99%