This paper presents an application of Composite Right/Left-Handed (CRLH) Transmission Line resonators for compact mass flow detectors with increased sensitivity compared to conventional microwave mass flow detectors. In this concept series capacitors and shunt inductors are used to synthesize a medium with simultaneously negative permeability and permittivity -the so called metamaterial. The simultaneous detection of the velocity and the solids/air concentration from a single measurement, ensures a true mass flow detector. The helix shape of the cylindrical CRLH-TL sensor offers the possibility to detect flow inhomogeneities within the pipeline that can be applied to increase the accuracy of the detector. The rearrangement of two CRLH-TL resonators can reduce the necesasary sensorlength of the sensor and at the same time increase the sensitivity of irregularities in homogeneous distributed flows. Prototypes of both sensor structures were realized and tested in a dedicated measurement setup to prove the concept. The application areas of this sensor are gas/solids, gas/liquid and liquid/solids flows in various industrial monitoring applications.