Cross-section measurements of neutron-induced reactions on GaAs using monoenergetic beams from 7.5 to 15 MeV

Abstract: Cross-section measurements for neutron induced reactions on GaAs have been carried out at twelve different neutron energies from 7.5 to 15 MeV using the activation technique. The monoenergetic neutron beams were produced via the 2 H(d, n) 3 He reaction. GaAs samples were activated along with Au and Al monitor foils for determining the incident neutron flux. The induced activities of the reaction products were measured using high-resolution γ-ray spectroscopy. Cross-section for five reaction channels viz., 69 G… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
7
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 25 publications
(9 citation statements)
references
References 17 publications
2
7
0
Order By: Relevance
“…The relative efficiency data with and without absorber for a particular target detector geometry inclusive of all due to self scattering, self absorption and geometry solid angle for a simulated cylindrical target was used to determine the cross sections. The cross section measured in the present work and by others [4][5][6][7][8][9][10][11][12][13] with the same experimental method are in agreement within about 2-15 %.…”
Section: Resultssupporting
confidence: 90%
See 1 more Smart Citation
“…The relative efficiency data with and without absorber for a particular target detector geometry inclusive of all due to self scattering, self absorption and geometry solid angle for a simulated cylindrical target was used to determine the cross sections. The cross section measured in the present work and by others [4][5][6][7][8][9][10][11][12][13] with the same experimental method are in agreement within about 2-15 %.…”
Section: Resultssupporting
confidence: 90%
“…The previous measurements of (n,2n) cross sections around 14.0 MeV neutron energy on these isotopes show a 7-34% spread [4][5][6][7][8][9][10][11][12][13] , so further measurements are needed.…”
Section: Introductionmentioning
confidence: 98%
“…The associated half-life times are in very good agreement with the literature values from the National Nuclear Data Center database [28]. The incident neutron flux and the reaction cross section for 238 U(n,2n) 237 U was calculated from the well-known activation formula [38][39][40]…”
Section: Discussionsupporting
confidence: 71%
“…1 and 2). Raut's [2] measurements are lower than all other measurements. It is noted that the experimen-tal measurements for the 75 As(n,2n) 74 As reaction show the same behaviour (see Fig.…”
Section: Introductionmentioning