2005 European Conference on Power Electronics and Applications 2005
DOI: 10.1109/epe.2005.219521
|View full text |Cite
|
Sign up to set email alerts
|

Crowbar control algorithms for doubly fed induction generator during voltage dips

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
32
0
1

Year Published

2008
2008
2021
2021

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 46 publications
(34 citation statements)
references
References 2 publications
0
32
0
1
Order By: Relevance
“…It was shown that using PI rotor current controllers with low bandwidth the problem of stability is avoided, but the problem of low damping remains. Several methods for the improvement of the system are described in [3] and a simple method consisting in an inner control loop acting on the direct axis is presented in [4]. In [5] a quadrature stabilization method is proposed, and in [6], the method presented in [4] is compared with the method presented in [5].…”
Section: Introductionmentioning
confidence: 99%
“…It was shown that using PI rotor current controllers with low bandwidth the problem of stability is avoided, but the problem of low damping remains. Several methods for the improvement of the system are described in [3] and a simple method consisting in an inner control loop acting on the direct axis is presented in [4]. In [5] a quadrature stabilization method is proposed, and in [6], the method presented in [4] is compared with the method presented in [5].…”
Section: Introductionmentioning
confidence: 99%
“…The DC-link bus voltage can increase rapidly under these conditions, so it is also used as a monitored variable for crowbar triggering. Bidirectional thyristors [8], GTOs [5], [9] or IGBTs [10] are typically used for crowbar switching.…”
Section: A Crowbar Protectionmentioning
confidence: 99%
“…With the grid-connected rules are increasingly strict, it has become a mandatory problem that ensuring the wind power unit is not out-of-step under grid voltage dips. And according to the recent grid codes, wind turbines must have low voltage ride-through (LVRT) capability [1,2]. In wind turbines based on back-to-back converters, using the crowbar circuit is the most popular and reliable scheme to relieve the problems of overcurrent in rotor side converter (RSC) and overvoltage at DC-link during a severe voltage dip [3].…”
Section: Introductionmentioning
confidence: 99%