2007
DOI: 10.1016/j.bios.2006.04.001
|View full text |Cite
|
Sign up to set email alerts
|

CRP determination based on a novel magnetic biosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
82
0
1

Year Published

2008
2008
2021
2021

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 132 publications
(84 citation statements)
references
References 32 publications
1
82
0
1
Order By: Relevance
“…alternating and rotating) has recently become a potent tool for detection of proteins and molecules bound to the NPs. [1][2][3][4][5][6] To conduct a successful homogeneous magnetic bioassay, particularly in a rotating magnetic field (RMF), the iron oxide NP aqueous suspensions relaxing via the Brownian mechanism (d core > 24 nm) are required.…”
Section: Introductionmentioning
confidence: 99%
“…alternating and rotating) has recently become a potent tool for detection of proteins and molecules bound to the NPs. [1][2][3][4][5][6] To conduct a successful homogeneous magnetic bioassay, particularly in a rotating magnetic field (RMF), the iron oxide NP aqueous suspensions relaxing via the Brownian mechanism (d core > 24 nm) are required.…”
Section: Introductionmentioning
confidence: 99%
“…AuNPs on the surface have increased the sensitivity of the sensor. This method is more sensitive compared with other measurement methods based on related data have shown that (Meyer et al, 2002, Meyer et al, 2007Vikholm-Lundin et al, 2006). 87fM be determined until this study, low-range signal.…”
Section: Qcm Based Biosensors Developed For Determination Of Crpmentioning
confidence: 80%
“…The H-terminated NCD samples (homemade and Rho-BeSt) were immersed in this anti-CRP solution and incubated for 2 hours at 37 °C to allow physisorption of the antibodies through hydrophobic interactions, which results in reliable attachments [15,27]. The anti-CRP-coated NCD samples were subsequently incubated overnight in a 6% BSA solution in 1× PBS at 4 °C to block the remainder of the NCD surface that was not coated with anti-CRP.…”
Section: Ncd Synthesis and Functionalisationmentioning
confidence: 99%
“…Recently, these same authors developed a novel CRP determination method based on magnetic detection. They showed to be more sensitive than the typical hs-CRP ELISA assays [15]. In the last years, the focus on EIS-based immunosensing methods has increased significantly.…”
mentioning
confidence: 99%