2007
DOI: 10.1016/j.jbiomech.2007.02.021
|View full text |Cite
|
Sign up to set email alerts
|

Crushed bone grafts and a collagen membrane are not suitable for enhancing cartilage quality in the regeneration of osteochondral defects—An in vivo study in sheep

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 45 publications
0
5
0
Order By: Relevance
“…The same stain was used in the past to determine the chondrocyte clusters in the NP. 2,31 The present study showed that the Safranin O/FCF stain was best one for histopathological evaluations involving LDD, because it allows greater accuracy of the results, as it is easy to delimit the chondrocyte clusters in the NP.…”
Section: Discussionmentioning
confidence: 75%
“…The same stain was used in the past to determine the chondrocyte clusters in the NP. 2,31 The present study showed that the Safranin O/FCF stain was best one for histopathological evaluations involving LDD, because it allows greater accuracy of the results, as it is easy to delimit the chondrocyte clusters in the NP.…”
Section: Discussionmentioning
confidence: 75%
“…67,68 Schell et al transplanted types I and III collagen membrane with bone graft onto the fullthickness defect of the knee joint of sheep, but this resulted in no difference in cartilage repair compared to an empty control defect. 67 Ho et al covered the full-thickness cartilage defect in pig with PCL-collagen electrospun mesh with MSCs. After 6 months, the cartilage defect was partially covered with white reparative tissue.…”
Section: ■ Discussionmentioning
confidence: 99%
“…A few of the studies employed the electrospun mesh or collagen membrane on top of the defect to replace a periosteal flap for repairing cartilage defect. , Schell et al transplanted types I and III collagen membrane with bone graft onto the full-thickness defect of the knee joint of sheep, but this resulted in no difference in cartilage repair compared to an empty control defect . Ho et al covered the full-thickness cartilage defect in pig with PCL-collagen electrospun mesh with MSCs.…”
Section: Discussionmentioning
confidence: 99%
“…Absent Present detail elsewhere (14). In brief, specimens were fixed in 10% formalin, and dehydrated and embedded in methyl methacrylate, from which 6-mm-thick serial slices were made.…”
Section: Histologymentioning
confidence: 99%