Cryogenic characterization of Hamamatsu HWB MPPCs for the DUNE photon detection system

M. Andreotti,
S. Bertolucci,
A. Branca
et al.

Abstract: The Deep Underground Neutrino Experiment (DUNE) is a next generation experiment aimed to study neutrino oscillation. Its long-baseline configuration will exploit a Near Detector (ND) and a Far Detector (FD) located at a distance of ∼1300 km. The FD will consist of four Liquid Argon Time Projection Chamber (LAr TPC) modules. A Photon Detection System (PDS) will be used to detect the scintillation light produced inside the detector after neutrino interactions. The PDS will be based on light collec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…For the three XA configurations, 𝜏 t was found to range from 910 ns to 1510 ns corresponding to a maximal LAr purity correction (for the 910 ns value) of ∼ 10%. As for the SiPMs X-talk, it has been measured at 77 K (11.0 ± 1.0)% and (16.05 ± 0.32)% for the HPK [19] and FBK SiPMs respectively. The PDE assessed by the MiB method (𝜖 MiB ) is the average of the PDE values measured along the XA device length (usually 6-12 points) and accounts for the devices non uniformity as the SiPM-to-WLS gaps originated from the components tolerances, (slightly) different SiPMs gain etc.…”
Section: The Photon Detection Efficiency Of the Fd1 X-arapuca Devicementioning
confidence: 95%
See 1 more Smart Citation
“…For the three XA configurations, 𝜏 t was found to range from 910 ns to 1510 ns corresponding to a maximal LAr purity correction (for the 910 ns value) of ∼ 10%. As for the SiPMs X-talk, it has been measured at 77 K (11.0 ± 1.0)% and (16.05 ± 0.32)% for the HPK [19] and FBK SiPMs respectively. The PDE assessed by the MiB method (𝜖 MiB ) is the average of the PDE values measured along the XA device length (usually 6-12 points) and accounts for the devices non uniformity as the SiPM-to-WLS gaps originated from the components tolerances, (slightly) different SiPMs gain etc.…”
Section: The Photon Detection Efficiency Of the Fd1 X-arapuca Devicementioning
confidence: 95%
“…The number of detected photons is then corrected for the actual LAr yield, measured at each filling i.e. for each XA configuration by the LAr triplet half-life (𝜏 t ) [18], and for the SiPMs cross-talk [19]. At each filling, the 𝜏 t is measured and monitored along the one-day long PDE measurement campaign.…”
Section: The Photon Detection Efficiency Of the Fd1 X-arapuca Devicementioning
confidence: 99%