2015
DOI: 10.1097/prs.0000000000001236
|View full text |Cite
|
Sign up to set email alerts
|

Cryolipolysis for Fat Reduction and Body Contouring

Abstract: Background:Cryolipolysis is a nonsurgical technique for localized fat reduction. With the increased risk of complications from more invasive methods such as liposuction, cryolipolysis presents a promising method for nonsurgical body contouring. This study presents a systematic review of the available clinical data, with an emphasis on the efficacy, methods, safety, and complications of cryolipolysis.Methods:To identify clinical studies that assessed outcomes of cryolipolysis, a systematic review of the MEDLINE… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
101
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 137 publications
(103 citation statements)
references
References 26 publications
2
101
0
Order By: Relevance
“…As in other studies involving the treatment of fewer sites, erythema, numbness, and edema were most common, followed by a lesser incidence of tingling, and bruising 1, 2. In all cases, these signs and symptoms resolved without treatment.…”
Section: Discussionsupporting
confidence: 62%
See 2 more Smart Citations
“…As in other studies involving the treatment of fewer sites, erythema, numbness, and edema were most common, followed by a lesser incidence of tingling, and bruising 1, 2. In all cases, these signs and symptoms resolved without treatment.…”
Section: Discussionsupporting
confidence: 62%
“…Cryolipolysis (CoolSculpting System, ZELTIQ Aesthetics, Pleasanton, CA) is a non‐invasive procedure for the reduction of subcutaneous fat 1, 2, 3. Cryolipolysis received FDA clearance for the reduction of fat in the flank area in 2010.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Instead of measuring only periumbilical circumference, the Canfield Vectra system (figure 1) measures torso circumference at the umbilical reference point, and each 20 millimeters above and below the umbilical reference point. Table 1 shows the mean change in torso circumference per zone, with "0" being the umbilical reference point, "+20" being 20 mm above the umbilicus, and "-40" being 40 mm below the umbilicus.…”
Section: Methodsmentioning
confidence: 99%
“…Different people performing the measurement will certainly use a different technique.Ultrasound fat thickness has become more common as a measurement of localized fat reduction(23)(24)(25)(26)(27), especially when a noninvasive device is used. However, AA notes that outcome is highly dependent on operator expertise.…”
mentioning
confidence: 99%