CSR-Net: Cross-Scale Residual Network for multi-objective scaphoid fracture segmentation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 27 publications
(8 citation statements)
references
References 33 publications
0
8
0
Order By: Relevance
“… Ma, Zou & Liu (2021) added a context module to jump connections in the MHSU-Net network to reduce feature loss during segmentation. Chen et al (2021a) proposed cross-scale residual network (CSR-Net), which realizes the fusion of features from different layers through cross-scale residual connections and realizes the transformation between different scales and channels of the hierarchy to establish a close connection at different resolutions. Soulami et al (2021) proposed an end-to-end improved UNet model that combines residual fast and hybrid loss functions for detecting, segmenting, and classifying breast masses in one stage.…”
Section: Related Workmentioning
confidence: 99%
“… Ma, Zou & Liu (2021) added a context module to jump connections in the MHSU-Net network to reduce feature loss during segmentation. Chen et al (2021a) proposed cross-scale residual network (CSR-Net), which realizes the fusion of features from different layers through cross-scale residual connections and realizes the transformation between different scales and channels of the hierarchy to establish a close connection at different resolutions. Soulami et al (2021) proposed an end-to-end improved UNet model that combines residual fast and hybrid loss functions for detecting, segmenting, and classifying breast masses in one stage.…”
Section: Related Workmentioning
confidence: 99%
“…Finally, they removed small-sized predictions to decrease the false positive. Chen et al (2021a) proposed the cross-scale residual network (CSR-Net) to segment scaphoid fracture. This model allows a cross-scale residual connection to merge the features from different scales.…”
Section: Image Segmentationmentioning
confidence: 99%
“…The scaphoid fracture (ScaF) dataset is from Beijing Jishuitan Hospital, taken from the scaphoid fracture patients, and scanned with a TOSHIBA Aquilion PRIME equipment with 120 kV voltage and 180 mA current. We expanded this dataset to 84 cases based on our previous work (Chen et al 2021a). All CT images were cropped around the scaphoid bone to size of 128 × 128 × 128 per the guidance of clinical experts.…”
Section: Datasetsmentioning
confidence: 99%