Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Purpose To observe the technical and clinical outcome as well as safety of CT fluoroscopy-guided drain placement in the multimodal clinical complication management of superinfected gastric leakage after sleeve gastrectomy. Materials and Methods All consecutive patients who underwent CT fluoroscopy-guided drain placement to treat superinfected postoperative leakage after sleeve gastrectomy in our department between 2007 and 2014 were included in this retrospective study. All interventions were performed on a 16- or 128-row CT scanner under intermittent CT fluoroscopy guidance (15–25 mAs, 120 kV). The technical and clinical success rates as well as complications, additional therapies and patient radiation dose were analyzed. Results 14 patients (mean age: 43.8 ± 11.3 years, mean BMI: 52.9 ± 13.5, 7 women) who underwent a total of 31 CT fluoroscopy-guided drain placement procedures were included. 30 of 31 interventions (96.8 %) were technically successful. 7 patients underwent more than one intervention due to drain obstruction or secondary dislocation or as further treatment. During and after the intervention no procedure-associated complications occurred. In all patients, inflammation parameters decreased within days after the CT-guided intervention. The total interventional dose length product (DLP) was 1561 ± 1035 mGy*cm. Conclusion CT fluoroscopy-guided drain placement has been shown to be a safe minimally invasive procedure that rarely leads to complications for treating superinfected gastric leakage occurring after sleeve gastrectomy. We assume that operative revisions in a high-risk patient group can be avoided using this procedure. Key Points: Citation Format
Purpose To observe the technical and clinical outcome as well as safety of CT fluoroscopy-guided drain placement in the multimodal clinical complication management of superinfected gastric leakage after sleeve gastrectomy. Materials and Methods All consecutive patients who underwent CT fluoroscopy-guided drain placement to treat superinfected postoperative leakage after sleeve gastrectomy in our department between 2007 and 2014 were included in this retrospective study. All interventions were performed on a 16- or 128-row CT scanner under intermittent CT fluoroscopy guidance (15–25 mAs, 120 kV). The technical and clinical success rates as well as complications, additional therapies and patient radiation dose were analyzed. Results 14 patients (mean age: 43.8 ± 11.3 years, mean BMI: 52.9 ± 13.5, 7 women) who underwent a total of 31 CT fluoroscopy-guided drain placement procedures were included. 30 of 31 interventions (96.8 %) were technically successful. 7 patients underwent more than one intervention due to drain obstruction or secondary dislocation or as further treatment. During and after the intervention no procedure-associated complications occurred. In all patients, inflammation parameters decreased within days after the CT-guided intervention. The total interventional dose length product (DLP) was 1561 ± 1035 mGy*cm. Conclusion CT fluoroscopy-guided drain placement has been shown to be a safe minimally invasive procedure that rarely leads to complications for treating superinfected gastric leakage occurring after sleeve gastrectomy. We assume that operative revisions in a high-risk patient group can be avoided using this procedure. Key Points: Citation Format
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.