Cuff pressure monitoring by manual palpation in intubated patients: How accurate is it? A manikin simulation study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
18
1
8

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(28 citation statements)
references
References 21 publications
1
18
1
8
Order By: Relevance
“…Thus, for NIV masks, an objective measurement option to monitor and reduce pressures exerted on the face by NIV masks could be helpful to reduce pressure effects and optimise the mask fit. As a clinical comparison the estimation of endotracheal tube cuff inflation pressure by palpation is inadequate to determine an estimate of the pressure existing inside the cuff [ 27 ] and the objective monitoring of endotracheal tube cuff pressures has become a standard procedure during endotracheal intubation.…”
Section: Discussionmentioning
confidence: 99%
“…Thus, for NIV masks, an objective measurement option to monitor and reduce pressures exerted on the face by NIV masks could be helpful to reduce pressure effects and optimise the mask fit. As a clinical comparison the estimation of endotracheal tube cuff inflation pressure by palpation is inadequate to determine an estimate of the pressure existing inside the cuff [ 27 ] and the objective monitoring of endotracheal tube cuff pressures has become a standard procedure during endotracheal intubation.…”
Section: Discussionmentioning
confidence: 99%
“…70.7% of participants believe that the palpation measurement of the control balloon filling with air is sufficient and does not require the use of pressure gauges. It is worth emphasizing here that in Giusti et al [6] study , only 10% of respondents could correctly detect a pressure in the recommended range using manual palpation.…”
mentioning
confidence: 77%
“…A cuff pressure of < 20 cmH 2 O was found to be an independent risk factor for developing complications [22,24]. If the cuff has insufficient inflation pressure, it increases the risk of micro-aspirations and the passage gastric contents and contaminated secretions of the oral cavity into the trachea; this potentially causing aspiration pneumonitis and pneumonia, bronchitis as well as accidental extubation and selfextubation [22,[34][35][36][37]. A previous study has shown that if the pressure inside the cuff is kept < 20 cmH 2 O, the risk of the occurrence of VAP is increased by four times compared to higher cuff pressure [36].…”
Section: Problems Associated With Under-inflation Of Intracuff Pressurementioning
confidence: 99%