2019
DOI: 10.1186/s12887-019-1552-1
|View full text |Cite
|
Sign up to set email alerts
|

Current phototherapy practice on Java, Indonesia

Abstract: Background In Indonesia, the burden of severe hyperbilirubinemia is higher compared to other countries. Whether this is related to ineffective phototherapy (PT) is unknown. The aim of this study is to investigate the performance of phototherapy devices in hospitals on Java, Indonesia. Methods In 17 hospitals we measured 77 combinations of 20 different phototherapy devices, with and without curtains drawn around the incubator/crib. With a model to mimic the silhouette of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0
3

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 25 publications
0
11
0
3
Order By: Relevance
“…The current practice of maintenance for PT in Indonesia is to change the lamps based on hour-meters, or when the PT lamp has dimmed or died [ 9 ]. This study indicates that as PT devices are used, an unpredictable decrease occurs in the intensity of PT lamps, as measured by an intensity-meter.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The current practice of maintenance for PT in Indonesia is to change the lamps based on hour-meters, or when the PT lamp has dimmed or died [ 9 ]. This study indicates that as PT devices are used, an unpredictable decrease occurs in the intensity of PT lamps, as measured by an intensity-meter.…”
Section: Discussionmentioning
confidence: 99%
“…The fluorescent-based PT devices indicated more varied irradiance and several could only provide standard PT, with only two among nine fluorescent-based PT devices being able to provide intensive PT. It is extremely important for healthcare personnel to know the strengths and weaknesses of their PT devices [ 9 ]. This underlines the importance of having intensity meters in neonatal units.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…13 Sebuah laporan penelitian yang mengejutkan bahwa tingkat radiasi (irradiance levels) alat fototerapi di 17 rumah sakit di pulau Jawa yang mempunyai fasilitas perawatan neonatus level II dan III, didapatkan separuh alat fototerapi memiliki tingkat radiasi terlalu rendah (<10 μw/cm 2 /nm) dan beberapa RS terlalu tinggi. 14 Sebagian besar kasus ikterus neonatorum merupakan ikterus fisiologis, tetapi 3%-5% kasus merupakan proses patologis dan berisiko terjadi ensefalopati bilirubin/ kernikterus. 4,15,16 Sebanyak 25% kasus hiperbilirubinemia neonatal memiliki risiko gangguan bicara, bahasa, dan kelainan perkembangan lainnya 16 sehingga perlu deteksi dini dan pengelolaan dini yang efektif dan efisien.…”
Section: Hasilunclassified
“…[16][17][18][19][20][21] Various authors stress the importance of spectral irradiance measurements during PT that enables to adjust spectral irradiance to desired intensity levels. 4,6,9,10,14,15,22 Increasing the spectral irradiance of a PT device produces a faster decline of TSB levels. [23][24][25][26][27] Decades ago, Tan suggested a saturation point of 30 μW cm −2 nm −1 beyond which an increase in the spectral irradiance would not increase efficacy of PT.…”
Section: Introductionmentioning