2005
DOI: 10.1016/j.nima.2005.01.258
|View full text |Cite
|
Sign up to set email alerts
|

Current status of the small-angle station at Kurchatov center of synchrotron radiation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 19 publications
(9 citation statements)
references
References 7 publications
0
9
0
Order By: Relevance
“…Second, it is required to provide an optimum extension of the mirror surface reasoning from the angle ψ n of the field of view of the system (the angle of acceptance of the synchrotron beam). In [22], we calculated these parameters with the use of the following expression: where ψ n = arctan ψ 1 is the angular value of the X-ray beam above the mirrors which is not captured by them; U 1 and V 1 are the distance between the front end of the first mirror and the synchrotron source and the distance between the front end of the first mirror and the detector, respectively; l is the mirror length; and L τ is the distance between the front ends of the adjacent mirrors.…”
Section: Design Features Of the Stationmentioning
confidence: 99%
“…Second, it is required to provide an optimum extension of the mirror surface reasoning from the angle ψ n of the field of view of the system (the angle of acceptance of the synchrotron beam). In [22], we calculated these parameters with the use of the following expression: where ψ n = arctan ψ 1 is the angular value of the X-ray beam above the mirrors which is not captured by them; U 1 and V 1 are the distance between the front end of the first mirror and the synchrotron source and the distance between the front end of the first mirror and the detector, respectively; l is the mirror length; and L τ is the distance between the front ends of the adjacent mirrors.…”
Section: Design Features Of the Stationmentioning
confidence: 99%
“…In addition, the mirrors provide the suppression of higher harmonics of the fundamental wavelength. The four-shutter slits with independent control of each vertical and horizontal shutter are used in order to decrease the level of the background induced by the focusing elements [13,20,21].…”
Section: Equipment and Software Of The Stationmentioning
confidence: 99%
“…1) [13,21]. The horizontal aperture is equal to 1.2 mrad for a distance of 14 m to the emission point.…”
Section: Equipment and Software Of The Stationmentioning
confidence: 99%
“…The development of instrumentation allowed us to create X ray diffraction stations at the operating chan nels of SR sources [10][11][12][13][14][15][16][17][18][19][20][21][22][23] designed for the following experiments: study of the structure and structural dynamics of skeletal muscle and epithelial tissues in normal and pathological states; study of the natural and engineering silk constructions; and the effect of the high frequency electrosurgical welding (HF weld ing) of biological tissues.…”
Section: Introductionmentioning
confidence: 99%