2007
DOI: 10.1016/j.compstruct.2006.05.026
|View full text |Cite
|
Sign up to set email alerts
|

Curvature mode shape-based damage detection in composite laminated plates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
134
0
1

Year Published

2010
2010
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 215 publications
(136 citation statements)
references
References 8 publications
1
134
0
1
Order By: Relevance
“…Three different types of damage in laminated composite beams have been successfully detected by the GFD [38,40]. It should be pointed out that the GFD bears no conventional physical meaning as compared to the FD, and it only serves as an indicator of damage.…”
Section: Mode Shape Analysis Using Modern Signalmentioning
confidence: 99%
See 2 more Smart Citations
“…Three different types of damage in laminated composite beams have been successfully detected by the GFD [38,40]. It should be pointed out that the GFD bears no conventional physical meaning as compared to the FD, and it only serves as an indicator of damage.…”
Section: Mode Shape Analysis Using Modern Signalmentioning
confidence: 99%
“…Recently, Qiao and his coworkers (i.e., Qiao et al, Hamey et al, Lestari and Qiao, Lestari et al [40,[71][72][73][74]) conducted a series of studies on using strain mode shapes measured from surface-bonded piezoelectric sensors to identify various damage in composite beam or plate structures. Hamey et al [71] evaluated several damage detection algorithms in carbon/epoxy composite beams with several possible damage configurations using directly measured curvature mode shape (strain mode shape).…”
Section: Traditionalmentioning
confidence: 99%
See 1 more Smart Citation
“…The damage can be detected when the measured and simulated dynamic parameter deviates appreciably from the value expected for a healthy structure. Many studies show how these parameters produce satisfactory damage diagnoses with an acceptable level of accuracy [3][4][5]. However the modal parameters are linked to the out of plane displacement, so that the behaviour of the structure is well known only in one direction.…”
Section: Quantitative Damage Parameter Selectionmentioning
confidence: 99%
“…The capability of this index to characterize damage was demonstrated on cracked aluminum plates. Qiao et al [10] employed the MC 2D method to detect delamination in a composite laminate. The presence, location, and size of the delamination were effectively detected.…”
Section: Introductionmentioning
confidence: 99%