2003
DOI: 10.1016/j.amjcard.2003.08.042
|View full text |Cite
|
Sign up to set email alerts
|

Cut-off value of coronary flow velocity reserve by transthoracic Doppler echocardiography for diagnosis of significant left anterior descending artery stenosis in patients with coronary risk factors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
36
0

Year Published

2005
2005
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 61 publications
(37 citation statements)
references
References 30 publications
1
36
0
Order By: Relevance
“…Indeed, a decrease in the release of endothelium-derived nitric oxide has been well documented in experimental animal models of hypertension as well as in hypertensive patients (23). Recently, we reported a significant correlation between CFVR, forearm endothelial function and asymmetric dimethylarginine, which is an endogenous (14,16).…”
Section: Discussionmentioning
confidence: 95%
See 1 more Smart Citation
“…Indeed, a decrease in the release of endothelium-derived nitric oxide has been well documented in experimental animal models of hypertension as well as in hypertensive patients (23). Recently, we reported a significant correlation between CFVR, forearm endothelial function and asymmetric dimethylarginine, which is an endogenous (14,16).…”
Section: Discussionmentioning
confidence: 95%
“…CFVR was defined as the ratio of hyperemic to basal MDV. We adopted a CFVR of less than 2.0 as the cut-off value for the presence of significant coronary arterial stenosis, as has been done in published reports (14,16).…”
Section: Cfvr Measurement Using Transthoracic Doppler Echocardiographymentioning
confidence: 99%
“…It is know that even as a "stand alone" technique TTE-CFR<2 has good sensitivity 89-92% and specificity 75-93% to predict significant LAD and PD coronary artery stenosis (>70% diameter stenosis) [2][3][4] . CFR-TTE together with 2-dimensional echocardiography provide better sensitivity up to 93% and still good specificity 80.6% for detection of diseased LAD 5 .…”
Section: Discussionmentioning
confidence: 99%
“…21 It was known that the cutoff value of CFR by echocardiography could be useful for the diagnosis of LAD stenosis. 22 In this paper, as changes of CFR at 8 months showed positive correlations with circulating angiogenic cells at day 1, the cutoff value of change of CFR was investigated for circulating angiogenic cell mobilization by a ROC curve. The result (Figure 4) showed that we could expect the recovery of CFR with an 82.61% sensitivity and 100% specificity if the absolute number of CD34+ cells was ≥5 ANC/μl.…”
Section: Discussionmentioning
confidence: 99%