2020
DOI: 10.1016/j.istruc.2020.02.016
|View full text |Cite
|
Sign up to set email alerts
|

Cyclic behaviour of elliptical-shaped reduced web section connection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
3
1

Relationship

1
9

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 27 publications
0
8
0
Order By: Relevance
“…A bilinear stressstrain profile was assumed with young's modulus of 210 GPa, tangent modulus of 2.1 GPa and Poisson's ratio of 0.3. Based on former numerical investigations done by many scholars [27], [28], and according to guide runs, mesh element size of 20 mm was chosen to model the tested beam. This element size wasn't too large to cause major changes in the obtained results and at the same time it wasn't too small to make the solution run last for too much time.…”
Section: Simulation Of Steel Beams With Web Opening Subjectedmentioning
confidence: 99%
“…A bilinear stressstrain profile was assumed with young's modulus of 210 GPa, tangent modulus of 2.1 GPa and Poisson's ratio of 0.3. Based on former numerical investigations done by many scholars [27], [28], and according to guide runs, mesh element size of 20 mm was chosen to model the tested beam. This element size wasn't too large to cause major changes in the obtained results and at the same time it wasn't too small to make the solution run last for too much time.…”
Section: Simulation Of Steel Beams With Web Opening Subjectedmentioning
confidence: 99%
“…In addition to local instability, another drawback of the large openings is the early failure of the beam section due to the significant effect of the shear-flexure interaction in the T sections remaining at the top and bottom of the large opening. Therefore, in order to reduce the depth of the web perforation, Davarpanah et al [10,11] introduced and studied the horizontal elliptical-shaped RWS connections. They suggested ranges for the purpose of choosing the geometric variables of the elliptical-cut and the reduced region to ensure that the formation of the plastic hinge is away from the column edge.…”
Section: Introductionmentioning
confidence: 99%
“…The typical representatives of the beam end weakening connection include the dog-bone connection and the web opening connection [7][8][9][10]. However, the beam weaken connection still has the deficiencies as follows.…”
Section: Introductionmentioning
confidence: 99%