Cyclic Fatigue Resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue Nickel-titanium Instruments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
105
2
22

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
2
2

Relationship

0
10

Authors

Journals

citations
Cited by 130 publications
(134 citation statements)
references
References 30 publications
5
105
2
22
Order By: Relevance
“…Although all the instruments presented same tip sizes (#25), they had different cross-sections, taper, and thermal treatment of NiTi, which affected their mechanical properties (2,8,12,15,20). In agreement with our results, previous studies have shown that EDM size 25, .08 taper had higher cylic fatigue resistance than thermal treated NiTi instruments, such as PTG, HCM, WaveOne Gold, Reciproc Blue (9,11,12,20).…”
Section: Discussionsupporting
confidence: 86%
“…Although all the instruments presented same tip sizes (#25), they had different cross-sections, taper, and thermal treatment of NiTi, which affected their mechanical properties (2,8,12,15,20). In agreement with our results, previous studies have shown that EDM size 25, .08 taper had higher cylic fatigue resistance than thermal treated NiTi instruments, such as PTG, HCM, WaveOne Gold, Reciproc Blue (9,11,12,20).…”
Section: Discussionsupporting
confidence: 86%
“…Interestingly, with the more severe insertion angle of 30° the thermally pre‐treated instrument Reciproc Blue fractured earlier than the M‐wire instrument, whereas with angles below 30°, the opposite had been measured (Pedullà et al ). The time to fracture from other studies on Reciproc Blue has been reported as 872 s (Keskin et al ), 325 s (De‐Deus et al ) or even 2875 NCF (Gündogar & Özyürek ). This phenomenon is explained by the authors who speculated that pre‐heated Reciproc Blue instruments are more flexible than Reciproc, but can absorb less stress (Pedulla et al ).…”
Section: Variables In Study Designsmentioning
confidence: 94%
“…Only Hyflex EDM files have a significantly increased cyclic fatigue resistance compared with ProTaper Gold, WaveOne Gold and Reciproc Blue (Kaval et al . , Gündoğar & Özyürek ). All four Gold and Blue heat‐treated NiTi systems create well‐centred preparation even in severely curved root canals (Elnaghy & Elsaka , Silva et al .…”
Section: Martensitic Niti Alloymentioning