“…During operation of CMCs hot‐section components, stochastic overloads may occur during cyclic‐fatigue loading 30,31 . In the present analysis, three typical stochastic loading spectrums (as shown in Figure 1) were considered in the FLS analysis, as follows: - Under cyclic fatigue loading at peak stress σ p , the constant stochastic stress σ s occurs at cycle number N 1 , N 2 , and N 3 with cyclic duration Δ N .
- Under cyclic fatigue loading at peak stress σ p , the increasing stochastic stresses σ s1 , σ s2 , and σ s3 occur at cycle number N 1 , N 2 , and N 3 with cyclic duration Δ N .
- Under cyclic fatigue loading at peak stress σ p , the decreasing stochastic stress σ s1 , σ s2 , and σ s3 occur at cycle number N 1 , N 2 , and N 3 with cyclic duration Δ N .
…”