2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134)
DOI: 10.1109/pess.2000.867512
|View full text |Cite
|
Sign up to set email alerts
|

Damping controller input-signal loss effects on the wide-area stability of an interconnected power system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0
1

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(11 citation statements)
references
References 3 publications
0
10
0
1
Order By: Relevance
“…Mekki et al [23] have proposed a solution based on the replacement of the lost remote signal by a similar local signal through the use of signal-loss detector. A nonlinear simulation has been carried out for 25 s to further demonstrate performance robustness of the controllers in the presence of system nonlinearities, including saturation.…”
Section: Robustness Validation and Non-linear Simulationsmentioning
confidence: 99%
“…Mekki et al [23] have proposed a solution based on the replacement of the lost remote signal by a similar local signal through the use of signal-loss detector. A nonlinear simulation has been carried out for 25 s to further demonstrate performance robustness of the controllers in the presence of system nonlinearities, including saturation.…”
Section: Robustness Validation and Non-linear Simulationsmentioning
confidence: 99%
“…Hence, the controller design problem boils down to solving this LMI. However, inequality (15) The necessary transformation through substitution of new controller variables requires a solution to the design problem given by (20) …”
Section: Centralized Damping Control Designmentioning
confidence: 99%
“…One of the concerns of centralized design using remote signals is the possible loss of one of the channels leading to unsatisfactory damping performance. Reference [20] has proposed a solution based on the replacement of the lost remote signal by a similar local signal through the use of a signal-loss detector. It is possible to adjust the phase characteristics of the replacement local signal by a prefilter of required gain and phase.…”
Section: Robustness Validation and Performance Evaluationmentioning
confidence: 99%
“…Power system stability and small signal transient performance are determined from these modes, and consequently, it is of great value to have knowledge of these modes in order to attain good power system security and the potential for maximum power transfer [6]. The modes can be determined using calculations based on knowledge of the power system and its components.…”
Section: Introductionmentioning
confidence: 99%