2021
DOI: 10.1055/a-1374-1223
|View full text |Cite
|
Sign up to set email alerts
|

Das konometrische Konzept für implantatgetragene Einzelkronen: die definitive Befestigung ohne Zement oder Schrauben

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 18 publications
0
2
0
Order By: Relevance
“…In the conometric connection, retention is achieved only through the frictional force developed at the abutment-cap interface. A perfect fit between the two surfaces and the absence of a marginal gap in the conometric connection are fundamental requirements to avoid failures and bacterial infiltration [35,36]. In attempts to further minimize inflammatory responses and enhance bone stability in the crestal area of the implant, numerous in vitro studies emphasized that a gap between the abutment and cap (2.04-2.064 µm) is necessary to prevent bacterial infiltration [37][38][39].…”
Section: Discussionmentioning
confidence: 99%
“…In the conometric connection, retention is achieved only through the frictional force developed at the abutment-cap interface. A perfect fit between the two surfaces and the absence of a marginal gap in the conometric connection are fundamental requirements to avoid failures and bacterial infiltration [35,36]. In attempts to further minimize inflammatory responses and enhance bone stability in the crestal area of the implant, numerous in vitro studies emphasized that a gap between the abutment and cap (2.04-2.064 µm) is necessary to prevent bacterial infiltration [37][38][39].…”
Section: Discussionmentioning
confidence: 99%
“…In the conometric connection, retention is given only by the frictional force that develops at the abutment-cap interface. The perfect fit between the two surfaces and the absence of marginal gap of the conometric connection is a fundamental requirement to avoid failures and bacterial infiltration [36,37]. In an attempt to further reduce inflammatory responses and maximize bone stability in the crestal area of the implant, many in vitro studies [38][39][40] have defined that in the conometric connection, the gap between abutment and cap (2.04-2.064 micron) was considered necessary to avoid bacterial infiltration phenomena.…”
Section: Discussionmentioning
confidence: 99%