2019
DOI: 10.1016/j.dib.2019.103739
|View full text |Cite
|
Sign up to set email alerts
|

Data on microbial community composition of sludge from high altitude wastewater treatment plants determined by 16S rRNA gene sequencing

Abstract: This work presented the sequences of activated sludge from two municipal wastewater treatment plants (WWTPs) located in a high altitude Plateau in Tibet, China (∼3650 m above the sea level). Sequencing data are the 16S rRNA gene amplicons of V4—V5 region that sequenced on an Illumina HiSeq PE250 platform. Data presented here include detail description and water quality parameters of the WWTPs as well as results of 16S rRNA gene sequences from their active sludges. The core microbial communities in the WWTPs we… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…[ 65 ] In brief, V4 region was amplified using the barcoded primer set: 515FB: 5“‐49 GTGYCAGCMGCCGCGGTAA‐3” and 806RB: 5“GGACTACNVGGGTWTCTAAT‐3” described. [ 66 ] Then, the amplicons were sequenced using Illumina MiSeq sequencing platform by generating paired‐end reads with 2 × 250 kit.…”
Section: Methodsmentioning
confidence: 99%
“…[ 65 ] In brief, V4 region was amplified using the barcoded primer set: 515FB: 5“‐49 GTGYCAGCMGCCGCGGTAA‐3” and 806RB: 5“GGACTACNVGGGTWTCTAAT‐3” described. [ 66 ] Then, the amplicons were sequenced using Illumina MiSeq sequencing platform by generating paired‐end reads with 2 × 250 kit.…”
Section: Methodsmentioning
confidence: 99%
“…The quality of the library was initially determined with a Qubit@2.0 Fluorometer (Thermo Scientific) and then Agilent Bioanalyzer 2,100 System (Agilent Technologies). Sequencing analysis was performed on an Illumina MIseq platform ( Chen et al, 2019 ) with a PE250 strategy. Raw reads (2 × 250 bp paired-end) were analyzed mainly through the pipeline of Quantitative Insights into Microbial Ecology (QIIME) ( Caporaso et al, 2010 ).…”
Section: Methodsmentioning
confidence: 99%
“…The quality of the library was initially determined with a Qubit@2.0 Fluorometer (Thermo Scientific) and Agilent Bioanalyzer 2100 System (Agilent Technologies), and then sequencing analysis was performed on an Illumina PE250 platform. 20 Raw reads (2 × 250 bp paired-end) obtained from MiSeq high-throughput sequencing were analyzed with the pipeline of Quantitative Insights into Microbial Ecology (QIIME). 21 Chimeras were filtered out using the QIIME's default program ChimeraSlayer, 22 and reads were clustered into operational taxonomic units (OTUs) using UPARSE, 23 with a threshold of 97% identity.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…The PCR products were purified, and then the sequencing libraries were established using a TruSeqDNA PCR-Free Sample Preparation Kit (Illumina) following the manufacturer’s protocols. The quality of the library was initially determined with a Qubit@2.0 Fluorometer (Thermo Scientific) and Agilent Bioanalyzer 2100 System (Agilent Technologies), and then sequencing analysis was performed on an Illumina PE250 platform . Raw reads (2 × 250 bp paired-end) obtained from MiSeq high-throughput sequencing were analyzed with the pipeline of Quantitative Insights into Microbial Ecology (QIIME) .…”
Section: Methodsmentioning
confidence: 99%