2015
DOI: 10.1016/j.aca.2015.08.038
|View full text |Cite
|
Sign up to set email alerts
|

DATINK pilot study: An effective methodology for ballpoint pen ink dating in questioned documents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(6 citation statements)
references
References 28 publications
0
5
0
1
Order By: Relevance
“…In the literature, we found that two different sheets of white paper with the same weight can influence the evaporation of 2-PE and in consequence the pen stroke dating. Until now, the literature 22,27,30,31 only used white paper with grammage varying from 75 up to 80 g m 2 in ballpoint ink dating studies. However, with growth of initiatives aimed at the recycling and preservation of natural resources, recycled paper will become a routine paper in offices, and the ageing behavior of pen inks in this kind of paper should be studied.…”
Section: Discussionmentioning
confidence: 99%
“…In the literature, we found that two different sheets of white paper with the same weight can influence the evaporation of 2-PE and in consequence the pen stroke dating. Until now, the literature 22,27,30,31 only used white paper with grammage varying from 75 up to 80 g m 2 in ballpoint ink dating studies. However, with growth of initiatives aimed at the recycling and preservation of natural resources, recycled paper will become a routine paper in offices, and the ageing behavior of pen inks in this kind of paper should be studied.…”
Section: Discussionmentioning
confidence: 99%
“…Finally, the extraction time (1, 5, 15, 30 and 45 min) and temperature (50 and 60 • C) were investigated by means of a four-step MHS-SPME procedure [37], Fig. 2e.…”
Section: Optimization Of the Mhs-spme Methodsmentioning
confidence: 99%
“…This representation should be linear through successive extractions. Additionally, the correlation coefficient as well as the β value should also be examined to ensure the absence of possible undesirable matrix effect or any adsorption effect [37]. In this sense, seven successive extractions were carried out under previously optimized conditions.…”
Section: Optimization Of the Mhs-spme Methodsmentioning
confidence: 99%
“…A document may consist of several entries made at different times, and questions may arise about whether a particular entry was made at a purported time. The expert analysis of these documents that can provide information on the inks’ deposition date is complex and usually involves advanced chemical and physical analysis [ 2 , 3 , 4 ].…”
Section: Introductionmentioning
confidence: 99%