2018 XIII International Conference on Electrical Machines (ICEM) 2018
DOI: 10.1109/icelmach.2018.8506953
|View full text |Cite
|
Sign up to set email alerts
|

DC Current and Torque Ripple Mitigation in Modular PMSG Drives for Multi-MW WECSs with Linear PWM Inverter Modulation

Abstract: The paper analyzes a torque and DC-current ripple mitigation strategy in a modular axial-flux permanent magnet synchronous generator for multi-MW Wind Energy Conversion Systems (WECSs). The machine modules are aligned with one another and driven by the same shaft. Each module is connected to its own two-level converter and the converters are paralleled at the DC side. In order to reduce the DC-side current harmonics and the ripple in the resultant torque, a phase shift between the converters' PWM carrier signa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2018
2018
2019
2019

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(16 citation statements)
references
References 11 publications
0
16
0
Order By: Relevance
“…In [7] the approach of sequential command applied to SPWM modulation was proposed. The expression for the DC side current was developed.…”
Section: B DC Bus Voltage Expression Under Spwm Modulationmentioning
confidence: 99%
See 2 more Smart Citations
“…In [7] the approach of sequential command applied to SPWM modulation was proposed. The expression for the DC side current was developed.…”
Section: B DC Bus Voltage Expression Under Spwm Modulationmentioning
confidence: 99%
“…Substituting the expression of the approximated DC side current, developed in [7], in (5), an approximate expression of…”
Section: B DC Bus Voltage Expression Under Spwm Modulationmentioning
confidence: 99%
See 1 more Smart Citation
“…An approximated analytical expression for the electromagnetic torque and the dc bus voltage was developed in [3,9], which shows the main harmonics in the torque and the dc voltage along with the dependencies of each harmonic on the shift angle of the carrier signal ψ c µ where µ is the module number (here, µ = 1, 2, 3, 4). Such analytical approximated expression proved to be accurate for estimating both harmonic order and amplitudes for both the torque and dc voltage when compared with results of a Simulink model [3]. The choice ψ c µ = {0 0 , 90 0 , 180 0 , and 270 0 } cancels the harmonics of the order (h = m f ± 3, 2m f , 3m f ± 3 where m f is the frequency modulation ratio) and the least order harmonics left in the torque and voltage expressions is 4m f .…”
Section: Harmonic Content Comparisonmentioning
confidence: 99%
“…The WECSs with Sequential Command was proposed in [3]. The conversion system involves the connection of a two-level IGBT converter with each module of the machine.…”
Section: Introductionmentioning
confidence: 99%