2019
DOI: 10.1109/tie.2018.2869364
|View full text |Cite
|
Sign up to set email alerts
|

DC Decoupling-Based Three-Phase Three-Level Transformerless PV Inverter Topology for Minimization of Leakage Current

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 11 publications
0
8
0
Order By: Relevance
“…Note that the input capacitor is excluded in the number of capacitors. Number of capacitors in the proposed inverter, inverters in References 10,12,14,19,29 is less than that in the inverters in References 16,20–22,28. The inverter in Reference 16 has damping resistors, but there are no damping resistors in the other inverters in Table 2.…”
Section: Resultsmentioning
confidence: 96%
See 3 more Smart Citations
“…Note that the input capacitor is excluded in the number of capacitors. Number of capacitors in the proposed inverter, inverters in References 10,12,14,19,29 is less than that in the inverters in References 16,20–22,28. The inverter in Reference 16 has damping resistors, but there are no damping resistors in the other inverters in Table 2.…”
Section: Resultsmentioning
confidence: 96%
“…Number of inductors in the proposed inverter and the inverter in Reference 19 is four, while it is six in the inverters in References 15,16,20–22, which is the most among the inverters in Table 2. Number of inductors in the inverters in References 8,10,12,14,17,18,28 is three, while it is two in the inverter in Reference 29, which is the least among the inverters in Table 2. There is no capacitor in the inverters in References 8,15,17,18 because of no output capacitors in the grid‐connected inverters.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The stray capacitance is affected by several factors, such as PV panel and chassis structure, the PV cell surface, the distance between cells, weather conditions, and type of common-mode filter [15], [16]. Contributions have been conducted on development of new topologies or solutions to lower the leakage current through modifying the CMV amplitude [20]. Especially, when utilizing SiC power devices with high switching frequency, it becomes critical to suppress leakage current by low or constant CMV amplitudes, which helps to mitigate the system high-frequency emission source [22].…”
Section: Introductionmentioning
confidence: 99%