2008
DOI: 10.1109/pesc.2008.4592317
|View full text |Cite
|
Sign up to set email alerts
|

DC link current minimization for high power current source motor drives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
18
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(18 citation statements)
references
References 28 publications
0
18
0
Order By: Relevance
“…The resonance in steady-state may be avoided by SHE, but when the transient events occur, the SHE has limited capability to damp the resonances [14]. The dc-link current minimization strategy for a high-power CSC was proposed in [15] to reduce system losses, where the CSI modulation index is kept at the maximum value while the current-source rectifier (CSR) is used to regulate the dc-link current. The dc-link current can be controlled by the delay angle adjustment (α control) of the CSR or by modulation index control (m a control) [16].…”
Section: System Control With Proposed Methodsmentioning
confidence: 99%
“…The resonance in steady-state may be avoided by SHE, but when the transient events occur, the SHE has limited capability to damp the resonances [14]. The dc-link current minimization strategy for a high-power CSC was proposed in [15] to reduce system losses, where the CSI modulation index is kept at the maximum value while the current-source rectifier (CSR) is used to regulate the dc-link current. The dc-link current can be controlled by the delay angle adjustment (α control) of the CSR or by modulation index control (m a control) [16].…”
Section: System Control With Proposed Methodsmentioning
confidence: 99%
“…This paper mainly focuses on the microgrid applications, where the voltages on both sides are generally controlled within a safe range for critical loads [1]. Additionally, in contrast to the voltage source converter, the modulation index is generally controlled high to reduce the converter loss for the current source converter [11]. In this way, the proposed method is very effective because the voltage difference between rectifier and inverter sides can be minimized.…”
Section: It Can Be Observed That the Best Pulse Pattern Arrange Is mentioning
confidence: 99%
“…Besides, there is a potential risk of overcurrent due to the phase-leg short circuit, which reduces the system reliability. On the other hand, the current source converters have the inherent current limiting capability and thus enhance the reliability [8][9][10][11]. Furthermore, they allow forbidden states in the case of voltage source converters that may cause short-circuit, being in case of current source a desirable possibility to achieve soft-switching operation [12].…”
mentioning
confidence: 99%
“…However, what reference current selection used, as well as the converter specific operation and parameters are not given in the paper. In Li et al (2009) the selection of flux level in a Current Source Inverter (CSI)-drive was studied to optimize the losses due to the dc-link current. In the same way it would be valuable to do a similar study also for a Voltage Source Inverter (VSI)-drive.…”
Section: Introductionmentioning
confidence: 99%