DC-Link Protection and Control in Modular Uninterruptible Power Supply

Abstract: In this paper, a DC-link voltage protection (DCVP) control method is proposed to address the DC-link overvoltage issue due to power back-feeding in parallel Uninterruptible Power Supply (UPS) system. The proposed control method is able to protect the inverter against the excessive DC-link voltage, which increases the system reliability and robustness. Moreover, a current sharing control strategy is proposed by online regulating the virtual resistance of each UPS module. The proposed current sharing control str… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
14
0
3

Year Published

2019
2019
2022
2022

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 34 publications
(17 citation statements)
references
References 36 publications
0
14
0
3
Order By: Relevance
“…Without the UPS systems, any power outages and fluctuations can result in hardware damage or data loss. The vast growth in data centers and cloud storage systems in the recent years has tremendously increased the demand for the UPS systems [18][19][20][21][22].…”
Section: Uninterruptible Power Supplymentioning
confidence: 99%
See 1 more Smart Citation
“…Without the UPS systems, any power outages and fluctuations can result in hardware damage or data loss. The vast growth in data centers and cloud storage systems in the recent years has tremendously increased the demand for the UPS systems [18][19][20][21][22].…”
Section: Uninterruptible Power Supplymentioning
confidence: 99%
“…Offline (standby), Line-interactive, and Online [18][19][20][21][22]. In the following subsections, these configurations will be described.…”
Section: Classification Of Ups Systemsmentioning
confidence: 99%
“…The inner current loop is designed to provide a sufficient damping and protect the inductor's current from an overcurrent. Finally, it should be noted that if the nonlinear load is connected as the sensitive loads, the harmonic compensator should be added in the voltage controller of DC/AC converter to enhance the harmonic rejection ability of the output voltage [23]. Note that the control strategy for the rectifier has been shown in Fig.…”
Section: ) Control Strategy For Dc/ac Inverters In On-line Ups Systemmentioning
confidence: 99%
“…This method, however, requires additional sensors, which may not be desirable from the reliability and cost points of view [19][20][21]. This is particularly true for the UPS systems where the "plug and play" function needs to be realized by expanding more UPS modules according to the client's requirement [22,23]. Therefore, a DC-link voltage control with sensor-less control strategy needs to be investigated.…”
mentioning
confidence: 99%
“…As fontes ininterruptas de energia (UPS -Uninterruptible Power Supplies) são equipamentos utilizados para proteger cargas críticas, como é o caso de sistemas de telecomunicações, data center e computação em nuvem, contra distúrbios que ocorrem na tensão fornecida pelas concessionárias de energia [1], [2]. Podem ser classificadas como off-line, interativa ou dupla conversão, sendo esta última reconhecida por apresentar o melhor desempenho dentre os tipos citados, alimentando a carga independentemente das condições da rede pública [1]. Cabe salientar que, por apresentarem dois estágios de conversão de energia, estas UPSs geralmente possuem um menor rendimento e um custo mais elevado que as demais [3].…”
unclassified