2020
DOI: 10.1049/iet-epa.2019.0535
|View full text |Cite
|
Sign up to set email alerts
|

DC‐link voltage control strategy of Z‐source inverter for high‐speed permanent magnet motor

Abstract: In order to widen the flux-weakening range of motors, this study proposed a DC-link voltage control strategy for highspeed permanent magnet motor drive systems powered by Z-source inverter. In this strategy, the DC-link voltage, also known as the output voltage of the impedance network, varies with the inverter output voltage and remains optimal at all times, whether in steady state or transient state. As for the shoot-through duty ratio and the modulation index, the two main control variables in the Z-source … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…A new sliding mode control system based on indirect control of the capacitor voltage is used to control the DC-link voltage to suppress the system fluctuation caused by the change of the given value or the motor load. Simulations and experiments verified the effectiveness of the proposed strategy [147].…”
Section: Z Source Converter Topologies For Various Electrical Applicationsmentioning
confidence: 70%
“…A new sliding mode control system based on indirect control of the capacitor voltage is used to control the DC-link voltage to suppress the system fluctuation caused by the change of the given value or the motor load. Simulations and experiments verified the effectiveness of the proposed strategy [147].…”
Section: Z Source Converter Topologies For Various Electrical Applicationsmentioning
confidence: 70%
“…Therefore, the capacitor voltage can be measured and the DC‐link voltage can be calculated based on the capacitor voltage using a mathematical model. This method improves the control accuracy and significantly reduces the system control cost [19].…”
Section: Designing the Dc‐link Voltage Controlmentioning
confidence: 99%
“…In Ref. [21], a control strategy and an implementation method are proposed for the DC chain voltage of the Z-source inverter to be used in the high-speed permanent magnet synchronous motor. However, the process of parameter setting is complex and the system is significantly affected by parameters.…”
Section: Introductionmentioning
confidence: 99%