2016
DOI: 10.1049/iet-rpg.2015.0517
|View full text |Cite
|
Sign up to set email alerts
|

DC‐side fault detection for photovoltaic energy conversion system using fractional‐order dynamic‐error‐based fuzzy Petri net integrated with intelligent meters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(17 citation statements)
references
References 25 publications
0
16
0
Order By: Relevance
“…The MPPT algorithm is used to estimate the MPPV, 19.09-19.36VDC, and maximum output power, 0.84-1.07kW, with temperatures in the range 20 • C-35 • C and solar radiation 0.40-1.00 kW/m 3 . For six boost DC-DC converters at the source and load sites, the duty ratio can be estimated to match the load or battery charge to the PV array [33,34,39,40]…”
Section: The Procedures Of Electronic Load Demand Responsesmentioning
confidence: 99%
See 1 more Smart Citation
“…The MPPT algorithm is used to estimate the MPPV, 19.09-19.36VDC, and maximum output power, 0.84-1.07kW, with temperatures in the range 20 • C-35 • C and solar radiation 0.40-1.00 kW/m 3 . For six boost DC-DC converters at the source and load sites, the duty ratio can be estimated to match the load or battery charge to the PV array [33,34,39,40]…”
Section: The Procedures Of Electronic Load Demand Responsesmentioning
confidence: 99%
“…where the ranges of duty ratio are about from 0.2 (rated load voltage, V L = 24VDC) to 0.50 (rated load voltage, V L = 48VDC), and t off the turn-off time and t on the turn-on time, T d = t off + t on [39]. Therefore, the exact voltages of the DC power source can be fixed under the various atmospheric conditions.…”
Section: The Procedures Of Electronic Load Demand Responsesmentioning
confidence: 99%
“…Therefore, the maximum output power (MOP) of each PV panel, P q,est , and total MOP, P est , can be estimated as LGF / UGF) [6,[11][12][13]. When any fault occurs in a PV panel, voltage, current, and power meters can be employed to measure the output power, P q,mea , of each panel, as seen in the measurement system in Figure 2(b).…”
Section: Maximum Output Power Estimation and Fault Feature Extractionmentioning
confidence: 99%
“…Previous studies [6][7] have proposed that use of the MPPT algorithm may prevent faults during periods of lower solar radiation and night-to-day transition, as the algorithm can locate the reference value at the maximum power point. When the measured output power is degraded, based on the electrical property, faults such as grounded faults, line-to-line faults, and open circuit faults can be identified [6,[11][12][13].…”
Section: Introductionmentioning
confidence: 99%
“…Traditionally, the differential or integral of the integer order has often been used in physical phenomenon or for the control of a system. For example, speed can be obtained through displacing the displacement, the curve can be integrated to obtain the area, and fuzzy PD or PID controllers are often applied in the control system, thereby providing good effects [3,6,8,9].…”
Section: Introductionmentioning