DC transformer requirements and fault operation analysis in PV medium voltage DC power collection system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…These aspects provide a general perception of potential converters and vary in terms of importance. However, the ride through capability is required for the applications which are commonly prone to DC faults and need quick fault recoveries such as wind farms and PV MVDC collectors since the DC system has low-inertia [85], [86]. The main applications of DC-DC converters dedicated to MVDC grids will be discussed comprehensively in the following subsections with a summary shown in Table III for the critical requirements that converters should have for each application.…”
Section: Applications Of Mvdc Convertersmentioning
confidence: 99%
See 2 more Smart Citations
“…These aspects provide a general perception of potential converters and vary in terms of importance. However, the ride through capability is required for the applications which are commonly prone to DC faults and need quick fault recoveries such as wind farms and PV MVDC collectors since the DC system has low-inertia [85], [86]. The main applications of DC-DC converters dedicated to MVDC grids will be discussed comprehensively in the following subsections with a summary shown in Table III for the critical requirements that converters should have for each application.…”
Section: Applications Of Mvdc Convertersmentioning
confidence: 99%
“…The bidirectional power flow capability is another possible feature that converters should have for DC grids interfaces [5], [58]. Required, using FBSMs with non-isolated converters [5], [71], [80], [83] Required, using FBSMs with non-isolated converters [82], [85] Required [86] Unnecessary [92], [93] Required [54], [65], [94] The isolated version of DC-DC converters such as MMC DAB converters is suitable for linking the MVDC to HVDC grids. This topology provides the isolation and the independency of both AC-DC stages.…”
Section: A DC Grids Interconnectionmentioning
confidence: 99%
See 1 more Smart Citation
“…The response of the DC SST is analyzed. The control of DC SST must ensure that in case of a voltage dip at MVDC terminals, the voltage of the LVDC bus remains stable [9]. Control for FRT of a DC-DC converter based on an isolated boost converter is presented in [10].…”
Section: Introductionmentioning
confidence: 99%