2013
DOI: 10.1109/tie.2012.2185017
|View full text |Cite
|
Sign up to set email alerts
|

Decoupled $dq$-Current Control of Grid-Tied Voltage Source Converters Using Nonparametric Models

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
32
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 90 publications
(32 citation statements)
references
References 26 publications
0
32
0
Order By: Relevance
“…However, as will be shown in the next section, the peculiarity in the dq case is that each component is represented by a 2×2 matrix. This is shown in (9) where Y c is the component admittance matrix.…”
Section: Hrma In Dq Domainmentioning
confidence: 99%
See 1 more Smart Citation
“…However, as will be shown in the next section, the peculiarity in the dq case is that each component is represented by a 2×2 matrix. This is shown in (9) where Y c is the component admittance matrix.…”
Section: Hrma In Dq Domainmentioning
confidence: 99%
“…The main challenge is the representation of the control loops. The controller are usually in dq domain [9] while HRMA is formulated in phase domain. Existing works [7] adopted Proportional Resonant (PR) controllers because they are easier to represent in phase domain.…”
Section: Introductionmentioning
confidence: 99%
“…for active and reactive current part (∆i dw and ∆i qw ). The mathematical model of LCL filter is based on two basic equations (5) and (6). By subsequent modifications and transformation into d, q "virtual" revolving system are obtained the final equations (7) and (8).…”
Section: Converter Control Strategymentioning
confidence: 99%
“…Hysteresis control and delta modulation controls are robust and simple, but its variable switching frequency expects special adaptation likes [5]. Widely used control technique is vector control based on simple PI controllers [6] and [7], but these methods show a very slow dynamic behaviour for single-phase system. Very promising control techniques are based on predictive controllers [8] and [9], this kind of controllers is high sensitive to the system model accuracy.…”
Section: Introductionmentioning
confidence: 99%
“…Other commonly solutions are based on using transformations such as αβ-frame [22], [23], dq-frame [24] or using three independent current controllers which structure has to be changed over every 60…”
Section: Introductionmentioning
confidence: 99%