Abstract:Presented in this article is a method for decoupling the speed and flux control of a three-phase permanent magnet synchronous motor (PMSM) during an open-circuit fault (OCF) using a current controller based on proportional resonant (PR) control techniques. The suggested control approach is relatively simple to implement and maintains good motor operation during the open circuit. PMSM performance under pre-fault, OCF, and post-fault conditions were investigated using Matlab/Simulink and an experimental setup ba… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.