2022
DOI: 10.1002/micr.30927
|View full text |Cite
|
Sign up to set email alerts
|

Deep inferior epigastric perforator flap preoperative planning: A comparative analysis between dynamic infrared thermography, computerized tomography angiography, and hand‐held Doppler

Abstract: Introduction: Hand-held Doppler (HHD) sonography and computerized tomography angiography (CTA) are the common assessment tools for deep inferior epigastric perforator (DIEP) flap preoperative planning. CTA is considered the gold standard method for preoperative perforator mapping but necessitates contrast medium and X-ray exposure. Dynamic infrared thermography (DIRT) does not have these drawbacks and allows the detection of hot and cold spots on a given body area. Our study aimed to compare DIRT, HHD, and CTA… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 45 publications
1
4
0
Order By: Relevance
“…The meta-analysis, comprising seven studies and 1429 observations, indicates that the overall sensitivity of perforator detection is estimated to be 0.8754 (95% CI: 0.7542; 0.9414). This suggests that the methods employed in the studies were generally effective in identifying perforators and are comparable to other imaging modalities such as CTA and dynamic infrared thermography, as reported in a recent comparative analysis [ 18 ]. Specifically, the sensitivity of CTA was 93.87% whereas handheld Doppler showed lower sensitivity values of 69.02%.…”
Section: Discussionsupporting
confidence: 53%
“…The meta-analysis, comprising seven studies and 1429 observations, indicates that the overall sensitivity of perforator detection is estimated to be 0.8754 (95% CI: 0.7542; 0.9414). This suggests that the methods employed in the studies were generally effective in identifying perforators and are comparable to other imaging modalities such as CTA and dynamic infrared thermography, as reported in a recent comparative analysis [ 18 ]. Specifically, the sensitivity of CTA was 93.87% whereas handheld Doppler showed lower sensitivity values of 69.02%.…”
Section: Discussionsupporting
confidence: 53%
“…By checking the intraoperative doppler sound, damage to the main pedicle can be reduced. In particular, it is expected to be more helpful in cases of random flap surgery, where it is difficult to predict the location of the pedicle ( 5 ).…”
Section: Discussionmentioning
confidence: 99%
“…In recent years, the technology has also been applied to the development of new drugs and preoperative preparations for clinical surgery [ 65 , 66 ]. According to one study, the accuracy and reliability of dynamic infrared thermography used in deep inferior epigastric perforator flap breast reconstruction were comparable to those of the well-recognized computed tomography angiography [ 67 ]. Infrared thermal imaging has also been used to analyze skin tissues and identify tissues whose imaging is uneven to diagnose gynoid lipodystrophy [ 68 ].…”
Section: Infrared Thermal Imaging Technologymentioning
confidence: 99%