2005
DOI: 10.1038/sj.eye.6701403
|View full text |Cite
|
Sign up to set email alerts
|

Deep sclerectomy augmented with mitomycin C

Abstract: Aims To investigate the comparative efficacy and safety of deep sclerectomy with and without intraoperative mitomycin C (MMC) application for lowering the intraocular pressure (IOP). Methods A total of 71 eyes of 71 consecutive patients who had routine deep sclerectomy (DS), nonaugmented (DS-noMMC) or with mitomycin C (DS-MMC) augmentation (0.2 mg/ml for 2 min) and follow-up of 4 months or more were identified from an ongoing prospective database on glaucoma surgery. Indications for MMC use were the presence o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
95
1

Year Published

2005
2005
2022
2022

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 73 publications
(98 citation statements)
references
References 30 publications
2
95
1
Order By: Relevance
“…32,33 There is also evidence for a similar role of MMC in primary DS. [34][35][36][37][38][39] The decision to use MMC during individual surgical cases was difficult to pinpoint from our database. Patients in the MMC group were slightly younger and probably had worse visual field (VF) mean deviation.…”
Section: Discussionmentioning
confidence: 99%
“…32,33 There is also evidence for a similar role of MMC in primary DS. [34][35][36][37][38][39] The decision to use MMC during individual surgical cases was difficult to pinpoint from our database. Patients in the MMC group were slightly younger and probably had worse visual field (VF) mean deviation.…”
Section: Discussionmentioning
confidence: 99%
“…In our experience, MMC can be regarded as an enhancement of the deep sclerectomy IOP-lowering effect without evidence of antimetabolite-related complications (Cillino et al 2005). On the other hand, MMC-augmented glaucoma surgery can be associated with a significantly higher frequency of late bleb leaks (Anand & Atherley 2005;Anand et al 2006). and Gaetano Lodato A detailed database search (Medline and PubMed) failed to show any report on the use of synthetic implant materials as adjuvants in penetrating glaucoma surgery (Jampel et al 2002;Wilkins et al 2005).…”
Section: Introductionmentioning
confidence: 98%
“…1,2,[11][12][13] Unfortunately, antimetabolite-augmented glaucoma surgery can be associated with a higher frequency of prolonged wound leaks, hypotony with choroidal effusions and maculopathy, thin avascular blebs, and/or bleb leaks with late infection. 9,14,15 Recently, a new biodegradable porous collagen-glycosaminoglycan (GAG) copolymer matrix implant has been proposed for glaucoma surgery on the basis of animal experiments. [16][17][18] Ologen (OLO) collagen matrix (Aeon Astron Europe BV, Leiden, The Netherlands) is a biodegradable collagen-GAG implant, available in various shapes and dimensions, that may maintain the hypotensive effect in glaucoma surgery and enhance the healing in other selected ophthalmic surgeries (eg, pterygium or strabismus).…”
Section: Introductionmentioning