2008
DOI: 10.1016/j.ijrobp.2008.07.023
|View full text |Cite
|
Sign up to set email alerts
|

Deformation of Prostate and Seminal Vesicles Relative to Intraprostatic Fiducial Markers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

11
89
2

Year Published

2012
2012
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 89 publications
(102 citation statements)
references
References 22 publications
11
89
2
Order By: Relevance
“…The conclusion of the study was that with the currently used margins of more than 4 mm and the treatment divided into fractions, the increase of rectum dose caused by prostate deformation can be negligible. These findings are supported in the studies by van der Wielen et al, (16) Dehnad et al, (20) and Deurloo et al (17) where fiducial markers implanted into the prostate and CT prostate delineation, respectively, were used to investigate the prostate deformation. Other studies 18 , 19 have found that prostate deformation can occur and is an important source of uncertainty in radiotherapy of prostate cancer.…”
Section: Introductionsupporting
confidence: 64%
See 3 more Smart Citations
“…The conclusion of the study was that with the currently used margins of more than 4 mm and the treatment divided into fractions, the increase of rectum dose caused by prostate deformation can be negligible. These findings are supported in the studies by van der Wielen et al, (16) Dehnad et al, (20) and Deurloo et al (17) where fiducial markers implanted into the prostate and CT prostate delineation, respectively, were used to investigate the prostate deformation. Other studies 18 , 19 have found that prostate deformation can occur and is an important source of uncertainty in radiotherapy of prostate cancer.…”
Section: Introductionsupporting
confidence: 64%
“…Both registration approaches assume no prostate deformation or change in prostate volume caused by differences in rectum or bladder filling between the scans or the use of an endorectal coil. This assumption is supported by studies where the prostate deformation was found to be present, but negligible, compared with the prostate movement relative to the pelvic bones 15 , 16 , 17 . A rigid registration will in cases where prostate deformations are present for example when using an endorectal coil result in a reduced coverage of the prostate volume during radiotherapy treatment.…”
Section: Discussionmentioning
confidence: 87%
See 2 more Smart Citations
“…Fiducial markers have been used in radiotherapy to assist with the registration process 4 , 7 , 8 , 12 . Normally, fiducial markers are placed inside or adjacent to the target volumes prior to the radiotherapy simulation and serve as surrogates to the target volumes.…”
Section: Introductionmentioning
confidence: 99%