2012
DOI: 10.4045/tidsskr.12.0148
|View full text |Cite
|
Sign up to set email alerts
|

Demensdiagnostikk - automatisert kvantifisering av hjernestrukturer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 33 publications
0
5
0
Order By: Relevance
“…Volumetry of brain structures is a surrogate marker of AD, and many disorders can cause regional or global atrophy in the brain [14]. Earlier studies have shown that fully automated volumetry with the software package NeuroQuant cannot be used alone clinically, but that it can support other clinical investigations in diagnosing Alzheimer's dementia [15]. …”
Section: Introductionmentioning
confidence: 99%
“…Volumetry of brain structures is a surrogate marker of AD, and many disorders can cause regional or global atrophy in the brain [14]. Earlier studies have shown that fully automated volumetry with the software package NeuroQuant cannot be used alone clinically, but that it can support other clinical investigations in diagnosing Alzheimer's dementia [15]. …”
Section: Introductionmentioning
confidence: 99%
“…The sensitivity and specificity measurements of these neuroimage techniques were performed by commercially available automatic quantitative MRI tools (NeuroQuant), [25,26,5154] PET (Scenium), [55,56] and clinical evaluation. [50,57] Two measures of each technique were used to perform these analyses.…”
Section: Discussionmentioning
confidence: 99%
“…All subjects underwent 3 Tesla non-contrast structural brain magnetic resonance imaging (MRI). Automated NeuroQuant software was used for brain volumetric analysis (50) and the following parameters were collected: total intracranial volume (ICV) (cm 3 ), hippocampal volume (HV) (cm 3 ), and inferior lateral ventricle volume (ILVV) (cm 3 ). The number and volume of white matter hyperintensities (WMHI) were measured using SPIN Software (SpinTech, Bingham Farms, MI).…”
Section: Methodsmentioning
confidence: 99%
“…Exclusion criteria were prespecified, limited to a history of glaucoma, allergy to mydriatic eye drops, curcumin, or vitamin E. All subjects underwent retinal fluorescence imaging with a confocal scanning laser ophthalmoscope (SLO Retia TM , CenterVue SpA; Figure 1A) that utilizes blue light for the excitation of curcumin emission to obtain fluorescent images of the retina (Figure 1B-C), following a previously reported study design (17,42,44). They also underwent standard neuropsychological testing conducted by a licensed neuropsychologist (DS), that included the Montreal Cognitive Assessment (MOCA), global (50) and the following parameters were collected: total intracranial volume (ICV) (cm 3 ), hippocampal volume (HV) (cm 3 ), and inferior lateral ventricle volume (ILVV) (cm 3 ).…”
Section: Methodsmentioning
confidence: 99%