2010
DOI: 10.1016/j.ijms.2010.01.005
|View full text |Cite
|
Sign up to set email alerts
|

Demonstrating the metrological compatibility of uranium isotope amount ratio measurement results obtained by GSMS, TIMS and MC-ICPMS techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
7
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 10 publications
0
7
0
Order By: Relevance
“…An international inter-laboratory comparison research was recently published, in which four expert metrological institutes [Instituto de Pesquisas Energéticas e Nucleares (IPEN, from Brazil), Institute for Reference Materials and Measurements (IRMM, from Belgium), Institut Français de Recherche pour l'Exploitation de la Mer (IFREMER, from France) and National Institute of Standards and Technology (NIST, from USA)] compared the measurement results of U-isotope ratios, specifically for UF 6 samples, obtained by GSMS, TIMS and MC-ICP-MS [93]. Four UF 6 samples, with 235 U abundances ranging from 0.5 to 3.5% were used.…”
Section: Inductively Coupled Plasma Mass Spectrometrymentioning
confidence: 99%
See 4 more Smart Citations
“…An international inter-laboratory comparison research was recently published, in which four expert metrological institutes [Instituto de Pesquisas Energéticas e Nucleares (IPEN, from Brazil), Institute for Reference Materials and Measurements (IRMM, from Belgium), Institut Français de Recherche pour l'Exploitation de la Mer (IFREMER, from France) and National Institute of Standards and Technology (NIST, from USA)] compared the measurement results of U-isotope ratios, specifically for UF 6 samples, obtained by GSMS, TIMS and MC-ICP-MS [93]. Four UF 6 samples, with 235 U abundances ranging from 0.5 to 3.5% were used.…”
Section: Inductively Coupled Plasma Mass Spectrometrymentioning
confidence: 99%
“…Four UF 6 samples, with 235 U abundances ranging from 0.5 to 3.5% were used. Gaseous UF 6 were directly analyzed by GSMS whereas the samples were transformed to uranyl nitrate solution, with the two-step reaction discussed in the last section, for analyses with TIMS and MC-ICP-MS [93]. Through a detailed analysis of the sources of measurement uncertainty, it was concluded that the precision of isotope ratio measurements (as RSD) are 0.012%, 0.025% and 0.060% for GSMS, TIMS and MC-ICP-MS, respectively [93].…”
Section: Inductively Coupled Plasma Mass Spectrometrymentioning
confidence: 99%
See 3 more Smart Citations