Demonstration of Athena X-IFU Compatible 40-Row Time-Division-Multiplexed Readout

Abstract: Time-division multiplexing (TDM) is the backup readout technology for the X-ray Integral Field Unit (X-IFU), a 3168-pixel X-ray transition-edge sensor (TES) array that will provide imaging spectroscopy for european space agency's Athena satellite mission. X-IFU design studies are considering readout with a multiplexing factor of up to 40. We present data showing 40-row TDM readout (32 TES rows + 8 repeats of the last row) of TESs that are of the same type as those being planned for X-IFU, using measurement and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
40
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 43 publications
(42 citation statements)
references
References 17 publications
2
40
0
Order By: Relevance
“…The star symbol is the expected demonstration of the readout of 3168 pixels with the XIFU/Athena flight model (FM). The data points are taken from the following publications, as annotated in the bottom plot: a = [195], b = [196], c = [9], d = [133], e = [197], f = [128]…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The star symbol is the expected demonstration of the readout of 3168 pixels with the XIFU/Athena flight model (FM). The data points are taken from the following publications, as annotated in the bottom plot: a = [195], b = [196], c = [9], d = [133], e = [197], f = [128]…”
Section: Discussionmentioning
confidence: 99%
“…The star symbol is the expected demonstration of the readout of 3168 pixels with the XIFU/Athena flight model (FM). The data points are taken from the following publications, as annotated in the bottom plot: a =[195], b =[196], c =[9], d =[133], e =[197], f =[128] (32 TESs + 8 repeats of the last row), g =[134], h =[135], i =[10], j =[198], k =[127], l =[148], m =[149], n =[114], o =[157].…”
mentioning
confidence: 99%
“…Experimental measurements were performed in a NIST 8column × 32-row TDM system and used the NASA LPA 2.5a TES array [15] from our previous work [6], [7]. Our previous work used a "mux18b" multiplexing chip, with parameters listed in the caption of Fig.…”
Section: Advances In Tdm Operation and Chip Designmentioning
confidence: 99%
“…TDM [4] is a highly mature TES-readout technology that is routinely used in 250-pixel scale TES spectrometers in a broad range of experimental applications [5]. Recent demonstrations have shown steadily improving energy resolutions [6], with the most recent result of (2.16 ± 0.006) eV at 6.9 keV meeting X-IFU requirements including engineering margins [7]. These advances have been driven by increases in TDM bandwidth and the development of techniques to mitigate the malign effects of settling transients.…”
mentioning
confidence: 99%
See 1 more Smart Citation