2007
DOI: 10.1016/j.jct.2006.07.004
|View full text |Cite
|
Sign up to set email alerts
|

Density, viscosity, isothermal (vapour+liquid) equilibrium, excess molar volume, viscosity deviation, and their correlations for chloroform+methyl isobutyl ketone binary system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
6
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 19 publications
2
6
0
Order By: Relevance
“…These fits show linear behaviors for density and refractive index with temperature, while for viscosity, this dependence is exponential. To obtain the respective dependencies on composition and temperature, we adopt the same procedure that was previously described. ,,, The appropriate number of significant digits was selected taking into account the experimental errors for density, refractive index, viscosity, and temperature reported above.…”
Section: Resultsmentioning
confidence: 99%
“…These fits show linear behaviors for density and refractive index with temperature, while for viscosity, this dependence is exponential. To obtain the respective dependencies on composition and temperature, we adopt the same procedure that was previously described. ,,, The appropriate number of significant digits was selected taking into account the experimental errors for density, refractive index, viscosity, and temperature reported above.…”
Section: Resultsmentioning
confidence: 99%
“…During the course of the experiments, the purity of solvents was monitored by density measurements. The density and refractive index values of the pure solvents are given in Table and compared with the literature values. …”
Section: Methodsmentioning
confidence: 99%
“…The density and refractive index values of the pure solvents are given in Table 1 and compared with the literature values. [14][15][16][17][18][19][20][21][22][23] Experimental Procedure. The mass of chemicals were determined using a Sartorius AG TE214S analytical balance with a precision of ( 1 • 10 -4 g. The solutions were prepared in molal base by filling glass vials with organic solvent and salen Schiff base ligand and are closed tightly to avoid moisture.…”
Section: Methodsmentioning
confidence: 99%
“…They were taken from our previous paper . Comparison of measured and literature data for densities and viscosities of MIBK is shown in Table . The observed differences between two sets of data (experimental and literature) are due to the apparatus calibration procedure, different sources of materials, different sorts and amounts of impurities, and different techniques of measurements (e.g., SVM 3000 viscometer, Anton Paar DMA 4500, Canon-Ubbelohde viscometers, and so forth).…”
Section: Methodsmentioning
confidence: 99%