Dental Color Standards: Shade Tab Arrangement

Abstract: Total color difference in relation to the lightest tab, followed by the tab division into an adequate number of groups, is recommended as a possible and universally applicable mode of tab arrangement in dental color standards.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
46
0
6

Year Published

2007
2007
2023
2023

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 61 publications
(53 citation statements)
references
References 6 publications
1
46
0
6
Order By: Relevance
“…[7][8][9][10][11][12][13][14] Despite these advantages, some less experienced dental professionals and those with limited knowledge of color, have difficulty in understanding the shade matching method and implementation of the lightnesschroma-hue concept. In addition, some users find a shade guide with 29 tabs on the same holder somewhat ''busy'' and confusing.…”
Section: Introductionmentioning
confidence: 99%
“…[7][8][9][10][11][12][13][14] Despite these advantages, some less experienced dental professionals and those with limited knowledge of color, have difficulty in understanding the shade matching method and implementation of the lightnesschroma-hue concept. In addition, some users find a shade guide with 29 tabs on the same holder somewhat ''busy'' and confusing.…”
Section: Introductionmentioning
confidence: 99%
“…This system was developed in 1956, and since that time, researchers have pointed out its inherent flaws: lack of uniformity and limited color space coverage of natural teeth. [10][11][12][13][14][15][16] A newer type of shade guide, Vita Bleachedguide 3D-Master (BG, Vita Zahnfabrik, Bad Sä ckingen, Germany) displays a greater emphasis on the extra light area of the tooth color space and is designed primarily for use with bleached teeth. When compared to the VC guide, the BG has a wider color range (almost doubled), more uniform color distribution, and a visually perceived light-to-dark value order that precisely matches the manufacturers' suggested tab arrangement.…”
mentioning
confidence: 99%
“…En la tabla 1 se muestran todos los valores obtenidos de la medición del color en los 30 dientes por los tres evaluadores y los dos instrumentos, clasificados en grupos y transformados a valor cuantitativo según la tabla de Paravina y colaboradores (13 El análisis de concordancia kappa se realizó comparando por pares a los evaluadores entre sí, los evaluadores y los espectrofotómetros y los espectrofotómetros entre sí. En general, se encontraron índices k de fuerza baja y débil de concordancia, con intervalos de confianza 95 % de una gran amplitud.…”