2014
DOI: 10.4172/2161-105x.1000209
|View full text |Cite
|
Sign up to set email alerts
|

Depicting Respiratory Characteristics of Blood Pressure Signal by Using Empirical Mode Decomposition

Abstract: Aim: To explore adequate parameters for EMD of ABP signal; to determine the intrinsic characteristics of ABP waveform through the analysis of IMFs' averaged period and its energy density; to examine the effect of different respiration patterns on IMFs extracted from ABP waveform by CEEMD.Arterial blood pressure (ABP) reflects cardiac function, vessel compliance, and cardiorespiratory interaction and ABP analysis provides the estimators of this physiological information. But it is inconvenient for quantitative … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…It had been examined that the non-stationary characteristics of IMFs can be assessed by the spectral integration method with averaged period and corresponding energy density [14]. This method was originally used to study the characterization of intrinsic white noise by evaluating the distribution of IMFs' logarithmic averaged period and corresponding logarithmic energy density [15].…”
Section: Averaged Frequency and Energy Densitymentioning
confidence: 99%
See 2 more Smart Citations
“…It had been examined that the non-stationary characteristics of IMFs can be assessed by the spectral integration method with averaged period and corresponding energy density [14]. This method was originally used to study the characterization of intrinsic white noise by evaluating the distribution of IMFs' logarithmic averaged period and corresponding logarithmic energy density [15].…”
Section: Averaged Frequency and Energy Densitymentioning
confidence: 99%
“…The spectral analysis, such as FFT or DWT, was performed for quantitative assessment according to the specific fixed frequency band. In adaptive BPV based on EMD, the non-stationary intrinsic trends (IMF5-7 in this study) were extracted from ABP signal by EMD [14]. Each non-stationary intrinsic trend was assessed by the spectral analysis with averaged frequency and corresponding energy density for the comparison and the examination.…”
Section: Spectral Analysis Of Blood Pressure Variabilitymentioning
confidence: 99%
See 1 more Smart Citation