Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
SElectropalatography (EPG) is a useful tool for investigating tongue dynamics in experimental phonetic research and speech therapy. However, data provided by EPG are a two-dimensional representation in which all absolute positional information is lost. This paper presents an enhanced EPG (eEPG) system which uses digitised palate shape data to display the tongue-palate contact pattern in three dimenswns. The palate shapes are obtained using a colour-encoded structured light threedimensional digitisation system. The three-dimensional palate shape is displayed on a Silicon Graphics workstation as a surface made up of polygons represented by a quadrilateral mesh. EPG contact patterns are superimposed on to the three-dimensional palate shape by displaying the relevant polygons in a different colour. By using this system, differences in shape between individual palates, apparent on visual inspection of the actual palates, are also apparent in the image on screen. Further, methodr have been devised for computing absolute distances along paths lying on the palate surface. Combining this with calibrated palate shape data allows accurate measurements to be made between contact locations on the palate. These have been validated with manual measurements. In additwn, vocal tract areas in the oral cavity have been estimated by using the absolute measurements on the palate for a given contact pattern, and assuming a jlat tongue profie in the uncontacted area.*Current address: Medical Physics, St Thomas's Hospital, London SE17EH. CHIU, SHADLE AND CARTERElektropalatographie (EPG) bt zwar eine niitzliche Methode zur Untersuchung der Zungendynamik in der Experimentalphonetik und in der Sprachtherapie, aber aufgrund der z wei-dimensionalen Reprasentation von EPG-Daren geht die absolute Positionsinformation verloren. Dieser Beitrag beschreibt ein weiterentwickletes EPG-System, das digitalbierte Daten iiber die Form des Gaumens verwendet, um das Zungen-Gaumen-Kontaktmuster in drei Dimensionen darzustellen. Die Gaumenform wird mit einem 3-0 Digitalbierungs system errechnet, das mit farbkodiertem strukturiertem Licht arbeitet. Die drei dimensionale Gaumenform wird mit einer Silicon Graphics Arbeitsstation als eine aus einem viereckigen Netz bestehenden Polygonflache dargestellt. Die EPG-Kontaktmuster wird durch den Farbkontrast der betroffenen Polygone iiber die dreidimensionale Gaumenform gelegt. Durch den Einsatz diesen Systems, sind die Formunterschiede in den einzelnen Gaumen, die bei der Betrachtung der Gaumen selbst sofort zu erkennnen sin4 auch auf dem Bildschirm erkennbar. Methoden wurden entwickelt, um absolute Entfernungen auf der Gaumenoberflache zu berechnen. In ihrer Verbindung mit der geeichten Gaumenform lassen sie die Kontaktpunkte auf dem Gaumen genau messen. Die Berechnungen wurden manuell bestatigt. Aufierdem wurden Vokaltraktquerschnittsflachen im Mundraum fiir verschiedene Kontaktmaster unter Beriicksichtigung der absoluten Messungen und mit der Annahme eines flachen Zungenprofils aufierhalb der Kontaktregio...
SElectropalatography (EPG) is a useful tool for investigating tongue dynamics in experimental phonetic research and speech therapy. However, data provided by EPG are a two-dimensional representation in which all absolute positional information is lost. This paper presents an enhanced EPG (eEPG) system which uses digitised palate shape data to display the tongue-palate contact pattern in three dimenswns. The palate shapes are obtained using a colour-encoded structured light threedimensional digitisation system. The three-dimensional palate shape is displayed on a Silicon Graphics workstation as a surface made up of polygons represented by a quadrilateral mesh. EPG contact patterns are superimposed on to the three-dimensional palate shape by displaying the relevant polygons in a different colour. By using this system, differences in shape between individual palates, apparent on visual inspection of the actual palates, are also apparent in the image on screen. Further, methodr have been devised for computing absolute distances along paths lying on the palate surface. Combining this with calibrated palate shape data allows accurate measurements to be made between contact locations on the palate. These have been validated with manual measurements. In additwn, vocal tract areas in the oral cavity have been estimated by using the absolute measurements on the palate for a given contact pattern, and assuming a jlat tongue profie in the uncontacted area.*Current address: Medical Physics, St Thomas's Hospital, London SE17EH. CHIU, SHADLE AND CARTERElektropalatographie (EPG) bt zwar eine niitzliche Methode zur Untersuchung der Zungendynamik in der Experimentalphonetik und in der Sprachtherapie, aber aufgrund der z wei-dimensionalen Reprasentation von EPG-Daren geht die absolute Positionsinformation verloren. Dieser Beitrag beschreibt ein weiterentwickletes EPG-System, das digitalbierte Daten iiber die Form des Gaumens verwendet, um das Zungen-Gaumen-Kontaktmuster in drei Dimensionen darzustellen. Die Gaumenform wird mit einem 3-0 Digitalbierungs system errechnet, das mit farbkodiertem strukturiertem Licht arbeitet. Die drei dimensionale Gaumenform wird mit einer Silicon Graphics Arbeitsstation als eine aus einem viereckigen Netz bestehenden Polygonflache dargestellt. Die EPG-Kontaktmuster wird durch den Farbkontrast der betroffenen Polygone iiber die dreidimensionale Gaumenform gelegt. Durch den Einsatz diesen Systems, sind die Formunterschiede in den einzelnen Gaumen, die bei der Betrachtung der Gaumen selbst sofort zu erkennnen sin4 auch auf dem Bildschirm erkennbar. Methoden wurden entwickelt, um absolute Entfernungen auf der Gaumenoberflache zu berechnen. In ihrer Verbindung mit der geeichten Gaumenform lassen sie die Kontaktpunkte auf dem Gaumen genau messen. Die Berechnungen wurden manuell bestatigt. Aufierdem wurden Vokaltraktquerschnittsflachen im Mundraum fiir verschiedene Kontaktmaster unter Beriicksichtigung der absoluten Messungen und mit der Annahme eines flachen Zungenprofils aufierhalb der Kontaktregio...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.