2021
DOI: 10.13052/2021.aces.j.361015
|View full text |Cite
|
Sign up to set email alerts
|

Design and Analysis of a Novel Linear Oscillating Actuator with Dual Stator Rectangular Geometry

Abstract: This paper proposes a new design of a linear oscillating actuator (LOA) with rectangular topology of stator and mover. The shape of a permanent magnet (PM) has a major impact on cost, mechanical strength and generation of magnetic flux density. This design uses rectangular PMs that are relatively cheaper than tubular PMs. Proposed LOA operates on single phase AC loading source. All the design parameters are optimized by using parametric sweep and the response of the LOA in terms of thrust force is compared. Th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…The resonance frequency of the LOAs are determined with the help of equation ( 2). Using equation ( 2), the resonance frequency of the LOA is determined through mover parameters; mover mass and spring stiffness (Jawad et al, 2021). As OMLOA has highest mover mass, it has lowest values of operating resonance frequency, shown by the blue line.…”
Section: Performance Results and Comparisonmentioning
confidence: 99%
“…The resonance frequency of the LOAs are determined with the help of equation ( 2). Using equation ( 2), the resonance frequency of the LOA is determined through mover parameters; mover mass and spring stiffness (Jawad et al, 2021). As OMLOA has highest mover mass, it has lowest values of operating resonance frequency, shown by the blue line.…”
Section: Performance Results and Comparisonmentioning
confidence: 99%
“…Design investigated in Ref. [8] is the rectangular structured LOA with axial magnetised PMs, housed on their mover. This topology is simple to fabricate and low cost, due to rectangular PMs used.…”
Section: F I G U R E 1 9 Stroke To Current Ratio Versus Frequency Of ...mentioning
confidence: 99%
“…The main problem of design examined in Ref. [8] is high leakage flux due open geometry. The design used in Ref.…”
Section: Comparison Of the Proposed Loa With Existing Topologiesmentioning
confidence: 99%
See 1 more Smart Citation
“…Consequence of the tubular structured LOA is challenged during manufacturing. Moreover, cost of tubular PMs is more than rectangular PMs (Jawad et al , 2021). LOA are used for different purposes, like compressor in refrigeration system (Bijanzad et al , 2020), electric hammer, linear pumps, bio-medical equipment and robots (Kim et al , 2020).…”
Section: Introductionmentioning
confidence: 99%